Installation instructions, Pressure testing – Zanussi ZUG 78 User Manual

Page 46

Advertising
background image

PRESSURE TESTING

To pressure test connect the pressure gauge to
the main oven injector
1 Check the supply pressure by turning the

grill on and oven thermostat to Mark 9. Then
turn on the electricity supply. Allow the grill
burner to light.
The pressure should be:
Natural Gas

20mbar

L.P.G. Gas

The pressure must be set to
28mbar for use on butane
or 37mbar for use on
propane.

2 Turn off the electricity supply and the

thermostat; disconnect the pressure gauge.

46