Fuse replacement, Xvh 5hsodfhphqw – Zebra Technologies Z6M User Manual

Page 76

Advertising
background image

68

Zebra Z4M/Z6M Printers User’s Guide

)XVH 5HSODFHPHQW

A user-replaceable AC power fuse is located just below the AC power switch at the
rear of the printer. The replacement fuse is a 3AG fast blow style rated at
5 Amp/250 VAC.

NOTE: Before replacing the fuse, turn off the AC power switch and unplug
the AC power cord.

1. To replace the fuse, insert the tip of a flat blade screwdriver into the slot in the end

of the fuse holder end cap.

2. Press in slightly on the end cap and turn the screwdriver slightly counterclockwise.

This disengages the end cap from the fuse holder and permits removal of the fuse.

3. To install a new fuse, remove the old fuse and insert the new fuse into the fuse

holder.

4. Push the end cap in slightly, then insert the tip of a flat blade screwdriver into the

slot in the end cap and turn clockwise to engage it.

Advertising