York PC9*DH User Manual

Page 5

Advertising
background image

246815-YTG-D-0108

Unitary Products Group

5

For additional connection diagrams for all UPG equipment refer to “Line Voltage System Wiring” document available on-line at
www.upgnet.com in the Product Catalog Section.

Thermostat Chart -

AC 26A

Two Stage Air Conditioner – Variable Speed Modulating Furnace

C

24 – Volt Common

Y1

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*PP32U70124

THERMOSTAT

AUX

Auxiliary Heat

R

24 – Volt Hot

(Heat XFMR)

R

24 – Volt Hot
(Cool XFMR)

C

24 – Volt Common

Y1

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*DN22U00124

THERMOSTAT

W2

Second Stage Heat

R

24 – Volt Hot

(Heat XFMR)

R

24 – Volt Hot
(Cool XFMR)

E/W1

Emergency Heat

E/W1

First Stage Heat

TWO STAGE

AIR

CONDITIONER

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

Y2

Second Stage

Compressor

C

24 – Volt Common

R

24 – Volt Hot

Y1

Single Stage Compressor

VARIABLE SPEED

MODULATING

FURNACE CONTROL

G

Fan

VARIABLE SPEED

MODULATING

FURNACE

Y/Y2

Second or Full

Stage Compressor

HUM

Dehumidification-

Open on Humidity Rise

W

Modulating Heat

Part Numbers:

SAP = Legacy

171334 = 031-09153

1

1

Move HUMIDISTAT

jumper to “YES”

if humidistat is to be used.

FL9C

FC9C

PC9

ID MODELS

External Humidistat

(Optional)

Open on Humidity Rise

24VAC Humidifier

(Optional)

External Humidistat

(Optional)

Open on Humidity Rise

2

2

Connection of the “C”

terminal, 24-Volt common

is optional when used with

batteries

Thermostat Installer Setup

0170-System Type-must

be set to 8-2 Heat/2 Cool

Multistage Conventional

Connection of the “C”

terminal, 24-volt common

is optional when used with

batteries

Thermostat Installer Setup

1-System Type-must

be set to 6-2 Heat/2 Cool

Multistage Conventional

Thermostat Installer Setup
15-Compressor Protection

-must be set to 5

Part Number:

S1-2HU16700124

2

Advertising