Test program – Yamaha AG-STOMP GA 011589 User Manual

Page 28

Advertising
background image

AG-Stomp

28

TEST PROGRAM

1

1

2

3

7

8

4

2

3

6

5

A.

CONNECTION OF TERMINALS

• INPUT

Monaural input

• OUT L/MONO

Balance output (RL 47K

)

• OUT R

Balance output (RL 47K

)

• HEAD PHONES

Stereo output (RL 33

)

• EXP. PEDAL

FC7 or Connect VR of B50K.

JK pin 1: MIN of VR JK pin 2: MAX of VR
JK pin 3: CENTER of VR

• DIGITAL OUT

Connect the DA converter.

• MIDI IN, MIDI OUT

Connect IN and OUT with the

DIN 5P cable.

• POWER SUPPLY

OFF

• AC IN

Connect the AC adaptor

B.

CONTENTS OF THE TEST PROGRAM

0: LED Check
1: SW Check
2: VR Check
3: MIDI Check
4: SRAM Check
5: FLASH ROM Check
6: DSP Check

C. STARTING THE TEST PROGRAM AND CHECKING

While pressing the MANUAL, STORE and ROOM
switches, turn on the POWER switch. The TEST
program will then be started. At this time, check to make
sure that the model name “AG.S” is displayed for about
2 seconds. The digit at the left end of the 7-segment
LED indicates the test No.

D. SELECTING THE TEST NUMBER

• Using the UP and DOWN switches, select the test
number and press the STORE switch to start testing.

E.

OPERATION OF THE TEST PROGRAM AND CHECKING
0: LED check

(1) Using the UP and DOWN switches, select “0”.
(This step can be skipped if “0” is already selected.)
(2) Press the STORE switch.
• LED segments light up one after another starting

with “UP”. When “MIC” is reached, “BANK”, “1”, “2”
and “3” light up followed by 7 segments in the
following order from the left end. After that, all LED
segments light up and go out.(Fig.1)

Fig.1

Advertising