Error messages – Yamaha AG-STOMP GA 011589 User Manual

Page 32

Advertising
background image

AG-Stomp

32

ERROR MESSAGES

If an error occurs during operation, one of the following error message numbers will appear in the display.
Stop operation of the AG-Stomp and follow one of the solutions described below.

E1

: MIDI Receive Buffer Full

CAUSE:

Too much MIDI data is being received and the buffer is full

SOLUTION: Try reducing the amount of data being sent, or break the data into smaller blocks.

E2

: Communication Error.

CAUSE:

An abnormality is detected during MIDI communications.

SOLUTION: Check all connections, etc. and try again.

E3

: Bulk Receive Check Sum Error.

CAUSE:

The check sum does not match the received MIDI bulk dump data.

SOLUTION: Check all connections and transmitted data, and try again.

E4

: Bulk Receive Data Abnormality.

CAUSE:

An abnormality is detected while receiving the bulk dump.

SOLUTION: Check all connections and transmitted data, and try again.