CHAPTER2 Ethernet Unit

Checkpoints

• Check the TELNET parameter to find

if it was set to stop operation during
logout.

• Check the TELNET parameter to find

if communication status is longer than
the time set for timeout.

• Check if a cable is detached or power

supply for the HUB or other equipment
is off.

• Check if operating problems are

occurring in devices such as the HUB
due to noise, etc.

• Too short of a period was set for the

no-response timeout period.

• Try substituting with another Ethernet

unit.

Action

• Always use a LOGOUT or BYE

command to terminate a TELNET
communication.

• Reset the parameter so operation

continues during logout.

• Set so communication time does not

exceed the timeout limit. Otherwise
increase the communication timeout
period or disable the timeout function.

• Check the network and repair/restore

any problem locations.

• Replace a device having operating

errors with another device.

• Set the no-response timeout period to

match the network structure and traffic
conditions. Or disable the timeout
function.

• If operation returns to normal, then the

Ethernet unit is defective so replace it.

No.

4

Probable causes

TELNET
communication
cuts off by itself
without a
LOGOUT or
BYE command
being issued.
TELNET
parameter was
set to stop
operation during
logout.
Communication
status continues
for a fixed period
and then cuts off
automatically at
timeout.
No-response
status continues
for a fixed period
versus the keep-
alive packet and
then cuts off
automatically at
timeout.
Ethernet unit is
defective.

1)

2)

3)

4)

5)

Symptom

Program
stops by itself
during
automatic
operation.