Appendix – Yamaha PLG100-DX User Manual

Page 42

Advertising
background image

42

Appendix

2.1.4.2 PLG100-DX Part Parameter Change

This message sets the PLG100-DX MULTI PART block (see Tables <2-1> and

<2-3>).

2.1.5 DX Parameter Change

11110000

F0H

Exclusive status

01000011

43H

YAMAHA ID

0001nnnn

1NH

N:Device Number

0ggggghh

GGH

Parameter Group No.

0ppppppp

PPH

Parameter No.

0vvvvvvv

VVH

Data

11110111

F7H

End of Exclusive

2.1.5.1 VCED parameter change

This message sets the VCED block (see Tables <3-1> and <3-2>).

2.1.5.2 ACED parameter change

This message sets the ACED block (see Tables <3-1> and <3-3>).

2.2 Bulk dump

This device uses only the following bulk dump messages.

[XG BULK DUMP]

1) XG System bulk dump
2) Multi Part bulk dump

[PLG100-DX NATIVE BULK DUMP]

1) System bulk dump
2) Part bulk dump

[DX BULK DUMP]

1) VCED
2) ACED
3) VMEM
4) AMEM

2.2.1 XG bulk dump

This message sets XG-related parameters. Unlike parameter change messages,

a single message can modify multiple parameters. The message format is as
follows.

11110000

F0H

Exclusive status

01000011

43H

YAMAHA ID

0000nnnn

0NH

N:Device Number

01001100

4CH

Model ID

0sssssss

SSH

ByteCountMSB

0ttttttt

TTH

ByteCountLSB

0ggggggg

GGH

Address High

0mmmmmmm

MMH

Address Mid

0lllllll

LLH

Address Low

0vvvvvvv

VVH

Data

:

:

0kkkkkkk

KKH

Check-sum

11110111

F7H

End of Exclusive

Address and Byte Count are given in tables <1-n>. Byte Count is indicated by

the total size of the Data in tables <1-n>.

Bulk dump is received when the beginning of the block is specified in “Ad-

dress”.

‘Block’ indicates the unit of the data string that is indicated in tables 1-n as

‘Total size’.

Check sum is the value that produces a lower 7 bits of 0 when the Start Address,

Byte Count, Data, and the Check sum itself are added.

2.2.1.1 XG System bulk dump

This message sets the XG SYSTEM block (see Tables <1-1>, <1-2>).

2.2.1.2 Multi Part bulk dump

This message sets the MULTIPART block (see Tables <1-1>, <1-3>).

2.2.2 PLG100-DX Native Bulk Dump

This message sets the special parameters for PLG100-DX. Unlike Parameter

change, one message can modify multiple parameters.

11110000

F0H

Exclusive status

01000011

43H

YAMAHA ID

0000nnnn

0NH

N:Device Number

01100010

62H

Model ID

0sssssss

SSH

ByteCountMSB

0ttttttt

TTH

ByteCountLSB

0ggggggg

GGH

Address High

0mmmmmmm

MMH

Address Mid

0lllllll

LLH

Address Low

0vvvvvvv

VVH

Data

:

:

0kkkkkkk

KKH

Check-sum

11110111

F7H

End of Exclusive

The details are the same as for 2.2.1 XG Bulk Dump. However, see Tables <2-

n> for the Address, Byte Count, and block.

2.2.2.1 PLG100-DX System Bulk Dump

This message sets the PLG100-DX SYSTEM block (see Tables <2-1>, <2-2>).

2.2.2.2 PLG100-DX Multi Part bulk dump

This message sets the PLG100-DX MULTI PART block (see Tables <2-1>, <2-

3>).

2.2.3 DX bulk dump

11110000

F0H

Exclusive status

01000011

43H

YAMAHA ID

0000nnnn

0NH

N:Device Number

0ttttttt

TTH

Format No.

0sssssss

SSH

ByteCountMSB

0ttttttt

TTH

ByteCountLSB

0vvvvvvv

VVH

Data

:

:

0kkkkkkk

KKH

Check-sum

11110111

F7H

End of Exclusive

Address and Byte Count are given in tables <3-n>. Byte Count is indicated by

the total size of the Data in tables <4-n>.

Bulk dump is received when the beginning of the block is specified in “Ad-

dress”.

“Block” indicates the unit of the data string that is indicated in tables 3-n as

“Total size”.

Check sum is the value that produces a lower 7 bits of 0 when the DATA, and

the Check-sum itself are added.

2.2.3.1 VCED Bulk Dump

This message sets the VCED block (see Tables <4-1> and <3-2>.

2.2.3.2 ACED Bulk Dump

This message sets the ACED block (see Tables <4-1> and <3-3>.

2.2.3.3 VMEM Bulk Dump

This message sets the VMEM block (see Tables <4-1> and <4-2>.

2.2.3.4 AMEM Bulk Dump

This message sets the AMEM block (see Tables <4-1> and <4-3>.

3. Realtime Messages

3.1 Active Sensing

a) Send
Do not send.
b) Receive
After FE is received one time, if the MIDI signal does not come within 400

msec, PLG100-DX will act the same as when ALL SOUND OFF, ALL NOTE
OFF, and RESET ALL CONTROLLERS are received, and return to the condi-
tion where FE has not been received once.

<1-1>
Parameter Base Address
MODEL ID = 4C

Parameter

Address

Description

(H)

(M)

(L)

XG SYSTEM

00

00

00

System

00

00

7E

XG System On

00

00

7F

All Parameter Reset

MULTI PART

08

00

00

Multi Part 1

:

08

0F

00

Multi Part 16

MULTI PART

0A

00

00

Multi Part 1

(additional)

:
:

0A

0F

00

Multi Part 16

PART ASSIGN

70

02

00

PLG100-DX Part Assign

Advertising