York SPLIT-SYSTEM YHJF18 THRU 60 User Manual

Page 14

Advertising
background image

510667-YTG-B-0509

14

Johnson Controls Unitary Products

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

COOLING PERFORMANCE DATA

CONDENSING UNIT MODEL NO. YHJF30S41S1
INDOOR COIL MODEL NO.

AHX36

CONDENSING

ENTERING AIR

TEMPERATURE

IDCFM

800

1000

1200

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

ID WB (°F)

57

62

62

67

72

57

62

62

67

72

57

62

62

67

72

65

T.C.

28.4

30.2

30.1

33.0

34.3

30.2

31.2

31.2

33.5

34.8

32.0

32.2

32.2

34.0

35.3

S.C.

28.4

26.3

22.5

22.3

18.2

30.2

29.6

24.6

23.7

18.7

32.0

32.2

26.8

25.1

19.1

KW

1.5

1.5

1.5

1.6

1.5

1.6

1.6

1.6

1.6

1.6

1.7

1.7

1.7

1.7

1.7

75

T.C.

27.3

28.7

28.7

31.5

33.2

29.0

29.7

29.6

32.1

33.7

30.7

30.6

30.6

32.7

34.2

S.C.

27.3

25.7

21.8

21.6

17.7

29.0

28.4

23.9

23.2

18.2

30.7

30.6

26.1

24.8

18.7

KW

1.7

1.7

1.7

1.7

1.7

1.8

1.8

1.8

1.8

1.8

1.9

1.9

1.9

1.8

1.8

85

T.C.

26.2

27.2

27.2

30.0

32.2

27.8

28.1

28.1

30.7

32.6

29.5

29.0

29.0

31.4

33.1

S.C.

26.2

25.0

21.1

21.0

17.1

27.8

27.3

23.3

22.8

17.7

29.5

29.0

25.4

24.6

18.4

KW

1.8

1.9

1.9

1.9

1.9

1.9

1.9

1.9

2.0

2.0

2.0

2.0

2.0

2.0

2.0

95

T.C.

25.1

25.8

25.8

28.6

31.1

26.7

26.6

26.6

29.3

31.5

28.2

27.3

27.3

30.1

32.0

S.C.

25.1

24.4

20.4

20.4

16.5

26.7

26.1

22.6

22.4

17.3

28.2

27.3

24.7

24.4

18.1

KW

2.0

2.0

2.0

2.0

2.1

2.1

2.1

2.1

2.1

2.1

2.2

2.1

2.1

2.2

2.2

105

T.C.

23.7

23.8

23.9

26.9

29.5

25.2

25.1

24.6

27.6

29.9

26.7

26.3

25.4

28.2

30.3

S.C.

23.7

23.4

19.6

19.7

15.7

25.2

25.1

21.7

21.7

16.6

26.7

26.3

23.9

23.7

17.5

KW

2.2

2.2

2.2

2.3

2.3

2.3

2.3

2.3

2.4

2.4

2.4

2.4

2.4

2.4

2.4

115

T.C.

22.2

21.9

21.9

25.2

27.8

23.7

23.6

22.7

25.8

28.3

25.2

25.2

23.4

26.4

28.7

S.C.

22.2

21.9

18.7

19.0

15.0

23.7

23.6

20.9

21.0

16.0

25.2

25.2

23.1

23.0

17.0

KW

2.4

2.4

2.4

2.5

2.5

2.5

2.5

2.5

2.6

2.6

2.6

2.6

2.6

2.7

2.7

125

T.C.

20.8

19.9

20.0

23.5

26.2

22.2

22.1

20.7

24.0

26.7

23.7

24.2

21.5

24.5

27.1

S.C.

20.8

19.9

17.8

18.3

14.2

22.2

22.1

20.1

20.3

15.3

23.7

24.2

21.5

22.3

16.4

KW

2.6

2.6

2.6

2.7

2.8

2.7

2.8

2.7

2.8

2.8

2.8

2.9

2.9

2.9

2.9

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Air Handler

Coil

T.C.

S.C.

KW

AV*36

0.99

0.98

1.09

F6FP42

0.99

0.98

1.09

MV12B

FC/MC43B

0.99

0.97

1.09

MV16C

FC/MC43C

0.99

0.97

1.09

Furnace

Coil

T.C.

S.C.

KW

T*(8,L)X*A12

FC/MC/PC37A

1.00

1.04

1.10

T*(8,L)X*B12

FC/MC/PC43B

1.01

1.05

1.11

T*(8,L)X*C16

FC/MC/PC43C

0.99

0.97

1.09

T*9X*B12

FC/MC/PC43B

1.00

1.04

1.10

T*9X*C16

FC/MC/PC43C

1.00

1.02

1.10

Y*(8,L)C*A12

FC/MC/PC37A

0.97

0.96

1.11

Y*(8,L)C*B12

FC/MC/PC43B

0.98

0.96

1.08

Y*(8,L)C*C16

FC/MC/PC43C

0.99

0.97

1.09

Y*(8,L)C*C20

FC/MC/PC43C

0.99

0.97

1.09

(Y*9C/T*9V)*B12

FC/MC/PC43B

0.99

0.99

1.13

(Y*9C/T*9V)*C16

FC/MC/PC43C

0.99

1.00

1.09

(Y*9C/T*9V)*C20

FC/MC/PC43C

0.99

0.97

1.09