York SPLIT-SYSTEM YHJF18 THRU 60 User Manual

Page 24

Advertising
background image

510667-YTG-B-0509

24

Johnson Controls Unitary Products

Multipliers for determining the performance with other indoor sections.

HEATING PERFORMANCE DATA

CONDENSING UNIT MODEL NO

YHJF42S41S1

EVAPORATOR COIL MODEL NO

AHX60

AIR TEMP.

ENTERING

OUTDOOR UNIT

AIR TEMP.

ENTERING

INDOOR COIL

ID CFM

1200

1400

1600

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

60

60

45.3

4.1

2.8

45.0

4.1

2.7

44.6

4.2

2.6

70

45.1

3.8

3.0

44.9

3.8

2.9

44.6

3.9

2.8

80

44.9

3.5

3.3

44.8

3.6

3.1

44.7

3.6

3.0

47

60

41.3

4.1

2.5

41.2

4.1

2.5

41.1

4.1

2.4

70

40.7

3.6

2.8

40.7

3.7

2.7

40.7

3.7

2.6

80

40.0

3.3

3.1

40.2

3.3

3.0

40.3

3.4

2.9

40

60

38.2

3.8

2.5

38.4

3.9

2.4

38.5

3.9

2.3

70

37.4

3.4

2.8

37.7

3.5

2.7

38.1

3.5

2.6

80

36.6

3.1

3.0

37.1

3.1

3.0

37.7

3.2

2.9

30

60

33.3

3.4

2.4

33.4

3.4

2.4

33.5

3.4

2.3

70

32.7

3.0

2.7

32.8

3.1

2.6

32.9

3.1

2.5

80

32.0

2.7

3.0

32.2

2.8

2.9

32.3

2.8

2.8

17

60

26.7

2.9

2.2

26.9

2.9

2.2

27.2

2.8

2.2

70

25.2

2.5

2.5

20.9

2.5

2.4

26.7

2.5

2.5

80

23.6

2.1

2.8

14.9

2.2

2.7

26.3

2.3

2.7

10

60

22.8

2.5

2.3

23.3

2.5

2.2

23.8

2.5

2.2

70

22.9

2.2

2.6

23.2

2.3

2.5

23.6

2.3

2.4

80

22.9

2.1

2.8

23.1

2.1

2.8

23.3

2.1

2.7

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Air Handler

Coil

MBH

KW

COP

F6FP060

1.01

1.01

1.00

MV20D

FC/MC62D

1.00

1.01

1.00

Furnace

Coil

MBH

KW

COP

T*(8,L)X*C16

FC/MC62D

1.00

1.02

0.99

T*(8,L)X*C20

FC/MC62D

1.01

1.02

0.99

T*9X*C16

FC/MC62D

1.01

1.00

1.02

T*9X*C20

FC/MC62D

1.00

1.01

1.00

T*9X*D20

FC/MC62D

1.00

1.01

1.00

Y*(8,L)C*C20

FC/MC62D

1.01

1.00

1.01

(Y*9C/T*9V)*C16

FC/MC62D

1.02

0.97

1.06

(Y*9C/T*9V)*C20

FC/MC62D

1.01

0.98

1.04

(Y*9C/T*9V)*D20

FC/MC62D

1.01

0.99

1.03

Advertising