HEATING PERFORMANCE DATA

E4TS048S06A WITH N1VSD2006 / G2FD060S24 - HIGH CFM 2-CYLINDER OPERATION

ID CFM

1420

1600

1750

OD DB

ID DB (°F)

MBTUH

1,2

KW

MBTUH

1,2

KW

MBTUH

1,2

KW

60

60

58.57

4.00

59.37

4.01

60.17

4.02

70

55.72

4.22

56.47

4.24

57.21

4.26

80

52.87

4.44

53.56

4.47

54.26

4.50

47

60

48.43

3.61

49.54

3.66

50.65

3.72

70

46.01

3.79

47.00

3.85

47.99

3.91

80

43.60

3.96

44.46

4.03

45.32

4.10

35

60

39.06

3.24

39.49

3.31

39.92

3.37

70

36.62

3.38

37.06

3.46

37.51

3.55

80

34.17

3.52

34.63

3.62

35.09

3.72

17

60

28.62

2.97

28.81

3.06

29.00

3.15

70

26.00

3.05

26.40

3.16

26.80

3.27

80

23.38

3.13

23.99

3.26

24.60

3.39

7

60

21.24

2.68

21.53

2.72

21.82

2.77

70

19.89

2.79

20.21

2.85

20.52

2.91

80

18.55

2.91

18.88

2.98

19.22

3.05

-3

60

14.73

2.48

14.93

2.53

15.13

2.57

70

13.79

2.58

14.01

2.64

14.22

2.70

80

12.86

2.69

13.09

2.76

13.32

2.82

E4TS048S06A WITH N1VSD2006 / G2FD060S24 - LOW CFM 1-CYLINDER OPERATION

ID CFM

850

1040

1140

OD DB

ID DB (°F)

MBTUH

1,2

KW

MBTUH

1,2

KW

MBTUH

1,2

KW

60

60

29.44

1.89

30.37

1.88

31.31

1.87

70

27.16

2.00

28.00

2.00

28.83

2.00

80

24.88

2.12

25.62

2.12

26.36

2.13

47

60

25.88

1.80

26.28

1.81

26.68

1.81

70

23.31

1.90

23.80

1.91

24.29

1.91

80

20.73

1.99

21.32

2.00

21.90

2.01

35

60

22.75

1.72

22.75

1.74

22.75

1.76

70

20.01

1.80

20.24

1.82

20.47

1.83

80

17.27

1.87

17.73

1.89

18.20

1.90

Air Handler

Coil

HIGH CFM

LOW CFM

MBTUH KW MBTUH KW

N1VSD20

G1FD061S24

1.02

1.00

0.95

0.95

F(2,3)FV060

1.00

1.00

0.93

0.95

Variable Speed
Furnace

Coil

MBTUH KW MBTUH KW

P1DUC16V

G1UA060S21

1.00

1.01

0.93

0.96

P1DUC16V

G1FA060S21

1.00

1.01

0.93

0.96

P1DUC20V

G1UA060S21

1.00

0.99

0.93

0.94

P1DUC20V

G1FA060S21

1.00

0.99

0.93

0.94

P1XUC20V

G1UA060S21

0.99

1.00

0.91

0.95

P1XUC20V

G1FA060S21

0.99

1.00

0.91

0.95

P1XDD20V

G2FD060S24

0.99

1.01

0.91

0.95

P1XDD20V

G2FD061H24

1.01

1.01

0.94

0.95

P1XUD20V

G1UA060S24

1.01

1.02

0.94

0.97

P1XUD20V

G1FA060S24

1.01

1.02

0.94

0.97

P1XUD20V

G2FD060S24

1.01

1.02

0.94

0.97

P1XUD20V

G2FD061H24

1.03

1.02

0.96

0.97

Air Handler

Coil

LOW CFM

MBTUH

KW

N1VSD20

G1FD061S24

1.02

1.00

F(2,3)FV060

1.00

1.00

Variable Speed
Furnace

Coil

MBTUH

KW

P1DUC16V

G1UA060S21

0.87

0.99

P1DUC16V

G1FA060S21

0.87

0.99

P1DUC20V

G1UA060S21

0.90

0.99

P1DUC20V

G1FA060S21

0.90

0.99

P1XUC20V

G1UA060S21

0.85

0.97

P1XUC20V

G1FA060S21

0.85

0.97

P1XDD20V

G2FD060S24

0.90

1.00

P1XDD20V

G2FD061H24

0.92

1.00

P1XUD20V

G1UA060S24

0.93

1.02

P1XUD20V

G1FA060S24

0.93

1.02

P1XUD20V

G2FD060S24

0.93

1.02

P1XUD20V

G2FD061H24

0.95

1.02

Advertising