22

Unitary Products Group

For notes see Page 11.

Multipliers for determining the performance with other indoor sections.

2-CYLINDER OPERATION

1-CYLINDER OPERATION

NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.

HEATING PERFORMANCE DATA

E4TS060S06A WITH N1VSD2006 / G2FD061S21 - HIGH CFM 2-CYLINDER OPERATION

ID CFM

1540

1860

2075

OD DB

ID DB (°F)

MBTUH

1,2

KW

MBTUH

1,2

KW

MBTUH

1,2

KW

60

60

65.76

4.68

66.22

4.71

66.68

4.74

70

63.45

4.98

64.33

5.02

65.20

5.07

80

61.15

5.27

62.43

5.33

63.72

5.40

47

60

56.89

4.31

57.80

4.39

58.70

4.47

70

54.00

4.51

55.00

4.61

56.00

4.70

80

51.10

4.71

52.20

4.82

53.30

4.93

35

60

46.70

3.92

47.54

4.04

48.37

4.16

70

43.54

4.04

44.43

4.17

45.31

4.30

80

40.38

4.17

41.32

4.30

42.25

4.44

17

60

29.71

3.45

30.61

3.58

31.51

3.70

70

28.44

3.50

29.20

3.68

29.96

3.86

80

27.16

3.55

27.79

3.79

28.41

4.02

7

60

21.86

2.75

22.24

2.81

22.63

2.87

70

20.78

2.86

21.19

2.94

21.60

3.02

80

19.70

2.96

20.14

3.06

20.57

3.16

-3

60

13.59

2.44

13.84

2.50

14.08

2.56

70

12.92

2.53

13.18

2.61

13.44

2.68

80

12.25

2.62

12.53

2.72

12.80

2.81

E4TS060S06A WITH N1VSD2006 / G2FD061S21 - LOW CFM 1-CYLINDER OPERATION

ID CFM

1000

1200

1350

OD DB

ID DB (°F)

MBTUH

1,2

KW

MBTUH

1,2

KW

MBTUH

1,2

KW

60

60

36.04

2.14

36.57

2.14

37.10

2.13

70

33.56

2.28

34.11

2.28

34.65

2.28

80

31.08

2.42

31.64

2.42

32.20

2.42

47

60

26.89

2.03

28.43

2.03

29.97

2.04

70

25.57

2.13

26.60

2.14

27.63

2.15

80

24.26

2.24

24.77

2.25

25.28

2.26

35

60

17.25

1.86

19.73

1.88

22.20

1.89

70

17.10

1.93

18.56

1.95

20.02

1.97

80

16.94

2.00

17.39

2.02

17.84

2.04

Air Handler

Coil

HIGH CFM

LOW CFM

MBTUH KW MBTUH KW

N1VSD20

G1FD060S24

0.98

1.00

0.93

0.98

F(2,3)FV060

0.98

1.00

0.93

0.98

Variable Speed
Furnace

Coil

MBTUH KW MBTUH KW

P1XDD20V112

G2FD060S24

0.98

0.99

0.90

0.94

P1XDD20V112

G2FD061H24

1.00

0.99

0.92

0.95

P1XUD20V112

G1UA060S24

0.98

0.98

0.90

0.93

P1XUD20V112

G1FA060S24

0.98

0.98

0.90

0.93

P1XUD20V112

G2FD060S24

0.98

0.98

0.90

0.93

P1XUD20V112

G2FD061H24

1.00

0.98

0.92

0.93

Air Handler

Coil

LOW CFM

MBTUH

KW

N1VSD20

G1FD060S24

0.89

0.91

F(2,3)FV060

0.88

0.90

Variable Speed
Furnace

Coil

MBTUH

KW

P1XDD20V112

G2FD060S24

0.88

0.95

P1XDD20V112

G2FD061H24

0.88

0.92

P1XUD20V112

G1UA060S24

0.87

0.95

P1XUD20V112

G1FA060S24

0.87

0.95

P1XUD20V112

G2FD060S24

0.87

0.95

P1XUD20V112

G2FD061H24

0.87

0.93

Advertising