We recommend that you write the data here:
Model (MOD.)

.........................................

Product number (PNC)

.........................................

Serial number (S.N.)

.........................................

Installation

Warning! Refer to "Safety information" chapter.

594

2

20

570

590

540

560

50

580

550 min

560÷

570

550 min

593

560-570

80÷100

A

B

Electrical installation

Important! The manufacturer is not responsible if you do

not obey the safety precautions from chapter "Safety".
This appliance is supplied without a main plug and a main

cable.

Applicable types of cables for Europe:
• Minimum size Cable/flex: 1,5mm²
• Cable/ flex type: H07 RN-F, H05 RN-F, H05 RRF, H05

VV-F, H05 V2V2-F (T90), H05 BB-F

• Fuse 13 A

Applicable types of cables for UK only

Connection via

Min. size Cable/flex

Cable/flex type

Fuse

• 13 A socket outlet
• 13 A spur box

2,5 mm²

Three core butyl insulated

13 A min.

Oven Control Circuit

2,5 mm²

PVC/PVC twin and earth

15 A min.

20 A min.