Serial Communications

Serial communications between the printer and the host computer can be set
by the

Y

command.

Y Command

Use the serial port setup (

Y

) command to change the communications

settings on the printer.

1. With the host computer set at the same communications settings as the

printer, send the

Y

command to change the printer to the desired

settings.

2. Change the host computer settings to match the new printer settings.

Refer to the programming guide for more information about this command.

Default the Serial Parameters

The default communications parameters on the printer are 9600 baud, no
parity, 8 data bits, 1 stop bit. Many utilities, downloaders and programs use
these settings.

16