Serial (RS-232) Connector

The printer operates as a Data Communication Equipment (DCE) and
normally connects via a standard RS-232 modem cable to a Data Terminal
Equipment (DTE) such as a computer or terminal with a default
configuration of 9600 baud, 8 bit data, 1 stop bit and No parity.

44

980483-001A

N/C

RxD

TxD

DTR

GND

DSR

RTS

RI

CTS

Printer

Host

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

DB-9

Pin #

DB-9

Pin #

Female DB-9 to Male DB-9

N/C

RxD

TxD

DTR

GND

DSR

RTS

RI

CTS

Printer

Host

1

8

2

3

3

2

4

20

5

7

6

6

7

4

8

5

9

22

DB-25

Pin #

DB-9

Pin #

Female DB-25 to Male DB-9

*+5 volts at 150 mA for external device (e.g. KDU or scanner)

+5 Volts*

TxD

RxD

CTS

GND

RDY

N/C

N/C

RDY

+5 Volts*

TxD

RxD

N/C

GND

RDY

N/C

N/C

RDY