Zephyr ASL-E42ASX User Manual

Page 12

Advertising
background image

www.zephyronline.com

Installa

tion - Ex

ternal & In-Line Blo

w

er P

repar

a

tion

The following instructions are for preparing the hood for use with an ex-

ternal or in-line blowers models CBE-1000 or PBN-1000A.
CAUTION: To reduce the risk of fi re and electric shock, install this rangehood
only with remote blowers rated maximum 6.2 A.

For internal blower instructions please turn to page 10.

1. Break out the partially pre-

cut circle in the lid, located
on the remote motor sup-
port bracket, using a fl at
head screwdriver. Fig. 1

2. Remove the cover by un-

doing the (3) screws. Fig. 2

3. Secure 8" round blower col-

lar to top of blower housing
using (4 type B) screws. Fig.3

4. Insert the female connector into the remote

motor support bracket enclosure. Fig.4

5. Pass the wires of the remote motor through the

hole in the cover that was previously removed
and connect them with those of the connector
located in the enclosure. Fig. 5

Note: Carry out the power supplly connection

in accordance with the national electric code,
ANSI/NFPA 70-1999.

- 12 -

Advertising