GENERAL

• Carefully read the following important information regarding installation
safety and maintenance. Keep this information booklet accessible for further
consultations.

POWER SUPPLY CONNECTION

For connection to the power supply refer to the following:

8. Break out the partially pre-cut circle in the

cover of the mains power connection en-
closure using a fl at head screwdriver. Fig.
15

9. Remove the power supply cover by un-

doing the (2) screws. Fig. 16

10. Connect the supply conduit to the cover,

then connect the hood to the power sup-
ply by making the following connections.
Fig.17:

BLACK = L line
WHITE = N neutral
GREEN / YELLOW = G ground

- A double-pole switch properly rated must

be installed to provide the range hood po-
wer supply disconnection.

- Connect the electrical conduit to the Field

Wiring Compartment using listed onduit
fi ttings.

- Carry out the power supplly connection in

accordance with the national electric code,
ANSI/NFPA 70-1999.

- 18 -