INSTALLATION

Securing The Oven To The Cabinet

Fit the appliance into the cabinet recess, open the
oven door and secure the oven to the kitchen cabinet
with four wood screws, which fit the holes provided in
the oven frame (Fig. 3).

Fig. 3

The oven designed to be connected to 240V (50Hz)
electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:

"L"

Live terminal

"N"

Neutral terminal

Earth terminal

THIS APPLIANCE MUST BE EARTHED

The cable used to connect the oven to the electrical supply
should have the characteristics indicated in the table.
If you require a direct connection to the electric network
(mains), it is necessary that you install an omnipole switch
between the appliance and the mains, with a minimum gap
of 3 mm between the switch contacts and a type suitable
for the required lead in compliance with the current rule.
This switch must be easily accessible to the user on
completion of the installation and must not break the yellow
and green earth cable at any point.
In order to connect the oven it is necessary to remove the

ELECTRICAL CONNECTION

plate at the back of the oven to reach the terminal block.
Connect the brown insulated wire to the terminal marked
"L".
Connect the blue insulated wire to the terminal marked "N".
Connect the green and the yellow insulated wire to the
terminal marked

.

Tighten the cable clamps ensuring that there is no
strain on the mains terminal.
Replace the cover and tighten securing screws.

Important

After installation and connecting, the cable must be
placed so that it cannot at any point reach a
temperature of more than 50

°

C above the ambient

temperature.
Before the appliance is connected, check that the main
fuse and the domestic installation can support the load;
and that the power supply is properly earthed.
The manufacturer disclaims any responsibility
should these safety measures not be carried out.
This appliance meets the requirements laid down in
EEC Directive No. 89/336 relating to the suppression
of radio and TV interference.

FOR UK USE ONLY

Fuse

Model

Cable cross

section mm

2

& type of the cable

ZBD 902

6 mm

2

Type 6242Y

30 A.

FOR OTHER EUROPEAN COUNTRIES

Lower oven

rating

Upper oven

rating

2870 W

2800 W

Fuse

Model

Cable cross

section mm

2

& type of the cable

ZBD 902

4 mm

2

HO7 RR-F

30 A.

Lower oven

rating

Upper oven

rating

2870 W

2800 W

FO 0143