Rs-232 se rial in ter face ca ble wiring 24, Serial interface communication configuration, Rs-232 serial interface cable wiring – Zebra Technologies 2742 User Manual

Page 28: Printer host

Advertising
background image

Serial Interface

Communication

Configuration

The printer’s serial port is configured with the

Y command for the printer. The printer supports

interface data rates from 1200 to 38,400 baud.

See the programmer's manual for details.

The printer’s serial port default configuration is:

9600 baud

8 bit data

1 stop bit

No parity

RS-232 Serial

Interface Cable

Wiring

The figure below displays the cable wiring re-

quired to use the printer’s serial interface.

24

980344-001 Rev.A

N/C

RxD
TxD

DTR

GND

DSR

RTS

RI

CTS

Printer

Host

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

DB-9

Pin #

DB-9

Pin #

Female DB-9 to Male DB-9

N/C

RxD
TxD

DTR

GND

DSR

RTS

RI

CTS

Printer

Host

1

8

2

3

3

2

4

20

5

7

6

6

7

4

8

5

9

22

DB-25

Pin #

DB-9

Pin #

Female DB-25 to Male DB-9

*+5 volts at 150 mA for external device (e.g. KDU or scanner)

+5 Volts*

TxD
RxD

N/C

GND

RDY

N/C

N/C

RDY

+5 Volts*

TxD
RxD

N/C

GND

RDY

N/C

N/C

RDY