ZyXEL Communications GS-2750 User Manual

Page 81

Advertising
background image

Chapter 7 Basic Setting

GS-2750 User’s Guide

81

Name

Type a descriptive name that identifies this port. You can enter up to 64 alpha-

numerical characters.

Note: Due to space limitations, the port name may be truncated in

some web configurator screens.

Type

This field displays 10/100/1000M for a 1000Base-T connection and the Dual

Personality interfaces, and 1000M for Mini-GBIC uplink ports.

Speed/Duplex

Select the speed and the duplex mode of the Ethernet connection on this port. The

choices are Auto, 10M/Half Duplex, 10M/Full Duplex, 100M/Half Duplex and

100M/Full Duplex for a 1000Base-T connection. 1000M/Full Duplex is supported by

both 1000Base-T (copper) and 1000Base-X (fiber-optic) connections.
Selecting Auto (auto-negotiation) allows one port to negotiate with a peer port

automatically to obtain the connection speed and duplex mode that both ends

support. When auto-negotiation is turned on, a port on the Switch negotiates with the

peer automatically to determine the connection speed and duplex mode. If the peer

port does not support auto-negotiation or turns off this feature, the Switch determines

the connection speed by detecting the signal on the cable and using half duplex

mode. When the Switch’s auto-negotiation is turned off, a port uses the pre-

configured speed and duplex mode when making a connection, thus requiring you to

make sure that the settings of the peer port are the same in order to connect.

Flow Control

A concentration of traffic on a port decreases port bandwidth and overflows buffer

memory causing packet discards and frame losses. Flow Control is used to regulate

transmission of signals to match the bandwidth of the receiving port.
The Switch uses IEEE 802.3x flow control in full duplex mode and backpressure flow

control in half duplex mode.
IEEE 802.3x flow control is used in full duplex mode to send a pause signal to the

sending port, causing it to temporarily stop sending signals when the receiving port

memory buffers fill.
Back Pressure flow control is typically used in half duplex mode to send a "collision"

signal to the sending port (mimicking a state of packet collision) causing the sending

port to temporarily stop sending signals and resend later. Select Flow Control to

enable it.

802.1p Priority This priority value is added to incoming frames without a (802.1p) priority queue tag.

See Priority Queue Assignment in

Table 11 on page 76

for more information.

BPDU Control

Configure the way to treat BPDUs received on this port. You must activate bridging

control protocol transparency in the Switch Setup screen first.
Select Peer to process any BPDU (Bridge Protocol Data Units) received on this port.
Select Tunnel to forward BPDUs received on this port.
Select Discard to drop any BPDU received on this port.
Select Network to process a BPDU with no VLAN tag and forward a tagged BPDU.

Apply

Click Apply to save your changes to the Switch’s run-time memory. The Switch loses

these changes if it is turned off or loses power, so use the Save link on the top

navigation panel to save your changes to the non-volatile memory when you are done

configuring.

Cancel

Click Cancel to begin configuring this screen afresh.

Table 13 Basic Setting > Port Setup (continued)

LABEL

DESCRIPTION

Advertising