General Specifications

General Specifications

90/96XiIII

140XiIII

170XiIII

220XiIII

Height

15.5" 393.7 mm 15.5" 393.7 mm 15.5" 393.7 mm 15.5" 393.7 mm

Width

9.15" 232.4 mm 11.15" 283.2 mm 13.15" 334.4 mm 15.65" 397.5 mm

Depth

19.5" 495.3 mm 19.5" 495.3 mm 19.5" 495.3 mm 19.5" 495.3 mm

Weight (without options)

50 lb 22.7 kg

55 lb 25 kg

67 lb 30.5 kg

72 lb 32.7 kg

Electrical

General (auto adjusting)

90-264 VAC;

48-62 Hz

90-264 VAC;

48-62 Hz

90-264 VAC;

48-62 Hz

90-264 VAC;

48-62 Hz

Power

consumption

Printing PAUSE

test label at

slowest speed

121 W

180 W

220 W

269 W

Printer idle

20 W

19 W

19 W

20 W

Compliance

Complies with FCC class “A” and Canadian Doc. class “A” rules.

Carries the CE mark of compliance.

Temperature

Operating

environment

Thermal transfer

41º to

104º F

5º to

40º C

41º to

104º F

5º to

40º C

41º to

104º F

5º to

40º C

41º to

104º F

5º to

40º C

Direct thermal

32º to

104º F

0º to

40º C

32º to

104º F

0º to

40º C

32º to

104º F

0º to

40º C

32º to

104º F

0º to

40º C

Storage

-40º

to

140º F

-40º

to

60º C

-40º

to

140º F

-40º

to

60º C

-40º

to

140º F

-40º

to

60º C

-40º

to

140º F

-40º

to

60º C

Relative

humidity

Operating environment

20 to 85%

non-condensing

20 to 85%

non-condensing

20 to 85%

non-condensing

20 to 85%

non-condensing

Storage

5 to 85%

non-condensing

5 to 85%

non-condensing

5 to 85%

non-condensing

5 to 85%

non-condensing

Zebra XiIII-Series User’s Guide