DIMENSIONS

COIL - MC

20

3/8”

(Opening)

A

C

3/4” Flange

B

22”

BOTTOM
OPENING
DIMENSIONS

D

20 1/4”

DIMENSIONS - MC COILS

Model

A

B

C

D

Refrigerant

Line Size

*

Factory

Installed

TXV (R22)

Model

A

B

C

D

Refrigerant

Line Size

Factory

Installed

TXV (R22)

Liquid Vapor

Liquid Vapor

MC18A2AH1

14.5

22

13 3/8 13.5

3/8

3/4

A

MC36C2AH1

21

26.5 19 7/8

20

3/8

7/8

A

MC18A3XH1

14.5

22

13 3/8 13.5

3/8

3/4

None

MC36C3XH1

21

26.5 19 7/8

20

3/8

7/8

None

MC18B2AH1

14.5

22

13 3/8 13.5

3/8

3/4

A

MC42B2CH1 17.5

32

16 3/8 16.5

3/8

7/8

C

MC18B3XH1

14.5

22

13 3/8 13.5

3/8

3/4

None

MC42B3XH1 17.5

32

16 3/8 16.5

3/8

7/8

None

MC24A2AH1

14.5

26.5

13 3/8 13.5

3/8

3/4

A

MC42C2CH1

21

32

19 7/8

20

3/8

7/8

C

MC24A3XH1

14.5

26.5

13 3/8 13.5

3/8

3/4

None

MC42C3XH1

21

32

19 7/8

20

3/8

7/8

None

MC24B2AH1

17.5

26.5

16 3/8 16.5

3/8

3/4

A

MC43C2CH1

21

26.5 19 7/8

20

3/8

7/8

C

MC24B3XH1

17.5

26.5

16 3/8 16.5

3/8

3/4

None

MC43C3XH1

21

26.5 19 7/8

20

3/8

7/8

None

MC30A2AH1

14.5

26.5

13 3/8 13.5

3/8

3/4

A

MC48C2CH1

21

32

19 7/8

20

3/8

7/8

C

MC30A3XH1

14.5

26.5

13 3/8 13.5

3/8

3/4

None

MC48C3XH1

21

32

19 7/8

20

3/8

7/8

None

MC30B2AH1

17.5

26.5

16 3/8 16.5

3/8

3/4

A

MC48D2CH1 24.5

32

23 3/8 23.5

3/8

7/8

C

MC30B3XH1

17.5

26.5

16 3/8 16.5

3/8

3/4

None

MC48D3XH1 24.5

32

23 3/8 23.5

3/8

7/8

None

MC35B2AH1

17.5

22

16 3/8 16.5

3/8

3/4

A

MC60D2CH1 24.5

32

23 3/8 23.5

3/8

7/8

C

MC35C2AH1

21

22

19 7/8

20

3/8

3/4

A

MC60D3XH1 24.5

32

23 3/8 23.5

3/8

7/8

None

MC35B3XH1

17.5

22

16 3/8 16.5

3/8

3/4

None

MC61D2CH1 24.5

36

23 3/8 23.5

3/8

7/8

C

MC35C3XH(1,2)

21

26.5/22 19 7/8

20

3/8

3/4

None

MC61D3XH1 24.5

36

23 3/8 23.5

3/8

7/8

None

MC36A2AH1

14.5

26.5

13 3/8 13.5

3/8

7/8

A

MC62C2CH1 21.0

36

19 7/8

20

3/8

7/8

C

MC36A3XH1

14.5

26.5

13 3/8 13.5

3/8

7/8

None

MC62C3XH1 21.0

36

19 7/8

20

3/8

7/8

None

MC36B2AH1

17.5

26.5

16 3/8 16.5

3/8

7/8

A

MC62D2CH1 24.5

36

23 3/8 23.5

3/8

7/8

C

MC36B3XH1

17.5

26.5

16 3/8 16.5

3/8

7/8

None

MC62D3XH1 24.5

36

23 3/8 23.5

3/8

7/8

None

All MC coils include a factory installed horizontal drain pan.
(3X) = Models require field installed TXV.

All MC coils include a factory installed horizontal drain pan.
(3X) = Models require field installed TXV.

*

Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin #690.01-AD1V for details.

Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin #690.01-AD1V for details.