12

Unitary Products Group

COIL - FC

20

3/8”

(Opening)

A

C

3/4” Flange

B

22”

BOTTOM
OPENING
DIMENSIONS

D

20 1/4”

DIMENSIONS - FC COILS

Model

A

B

C

D

Refrigerant

Line Size

*

Factory

Installed

TXV (R22)

Model

A

B

C

D

Refrigerant

Line Size

Factory

Installed

TXV (R22)

Liquid Vapor

Liquid Vapor

FC18A2AN1

14.5

18

13 3/8 13.5

3/8

3/4

A

FC36C2AN1

21

24.5 19 7/8

20

3/8

7/8

A

FC18A3XN1

14.5

18

13 3/8 13.5

3/8

3/4

None

FC36C3XN1

21

24.5 19 7/8

20

3/8

7/8

None

FC18B2AN1

14.5

18

13 3/8 13.5

3/8

3/4

A

FC42B2CN1 17.5

28

16 3/8 16.5

3/8

7/8

C

FC18B3XN1

14.5

18

13 3/8 13.5

3/8

3/4

None

FC42B3XN1 17.5

28

16 3/8 16.5

3/8

7/8

None

FC24A2AN1

14.5

22

13 3/8 13.5

3/8

3/4

A

FC42C2CN1

21

28

19 7/8

20

3/8

7/8

C

FC24A3XN1

14.5

22

13 3/8 13.5

3/8

3/4

None

FC42C3XN1

21

28

19 7/8

20

3/8

7/8

None

FC24B2AN1

17.5

22

16 3/8 16.5

3/8

3/4

A

FC43C2CN1

21

24.5 19 7/8

20

3/8

7/8

C

FC24B3XN1

17.5

22

16 3/8 16.5

3/8

3/4

None

FC43C3XN1

21

24.5 19 7/8

20

3/8

7/8

None

FC30A2AN1

14.5

22

13 3/8 13.5

3/8

3/4

A

FC48C2CN1

21

28

19 7/8

20

3/8

7/8

C

FC30A3XN1

14.5

22

13 3/8 13.5

3/8

3/4

None

FC48C3XN1

21

28

19 7/8

20

3/8

7/8

None

FC30B2AN1

17.5

22

16 3/8 16.5

3/8

3/4

A

FC48D2CN1 24.5

28

23 3/8 23.5

3/8

7/8

C

FC30B3XN1

17.5

22

16 3/8 16.5

3/8

3/4

None

FC48D3XN1 24.5

28

23 3/8 23.5

3/8

7/8

None

FC35B2AN1

17.5

20

16 3/8 16.5

3/8

3/4

A

FC60C2CN1

21

28

19 7/8

20

3/8

7/8

C

FC35C2AN1

21

20

19 7/8

20

3/8

3/4

A

FC60C3XN1

21

28

19 7/8

20

3/8

7/8

None

FC35B3XN2

17.5

20

16 3/8 16.5

3/8

3/4

None

FC60D2CN1 24.5

28

23 3/8 23.5

3/8

7/8

C

FC35C3XN(1,2)

21

24.5/20 19 7/8

20

3/8

3/4

None

FC60D3XN1 24.5

28

23 3/8 23.5

3/8

7/8

None

FC36A2AN1

14.5

24.5

13 3/8 13.5

3/8

7/8

A

FC62C2CN1

21

32

19 7/8

20

3/8

7/8

C

FC36A3XN1

14.5

24.5

13 3/8 13.5

3/8

7/8

None

FC62C3XN1

21

32

19 7/8

20

3/8

7/8

None

FC36B2AN1

17.5

24.5

16 3/8 16.5

3/8

7/8

A

FC62D2CN1 24.5

32

23 3/8 23.5

3/8

7/8

C

FC36B3XN1

17.5

24.5

16 3/8 16.5

3/8

7/8

None

FC62D3XN1 24.5

32

23 3/8 23.5

3/8

7/8

None

FC coils are not available with a factory installed horizontal drain pan.
(3X) = Models require field installed TXV.

FC coils are not available with a factory installed horizontal drain pan.
(3X) = Models require field installed TXV.

*

Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin #690.01-AD1V for details.

Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin #690.01-AD1V for details.