Specifications – Xantrex Technology FREEDOM SW 3000 User Manual

Page 75

Advertising
background image

975-0545-01-01

61

Specifications

NOTE: Specifications are subject to change without prior notice.

All inverter specifications are at nominal conditions: ambient temperature
of 77 °F (25 °C), 3000 watt resistive load, 12 volts DC inverting on the
RS3000, 120 volts AC, unless otherwise specified.

All charging specifications are at nominal conditions: ambient temperature
of 77 °F (25 °C), 120 VAC, 60 Hz input, unless otherwise specified.

Physical Specifications

Base Unit Dimensions and Weight:

L × W × H

385Ч340Ч200 mm (15.2Ч13.4Ч7.9 in.)

Net Weight

30.9 kg (68.1 lbs)

Inverter Specifications

Output wave form

Sine wave

Total harmonic voltage
distortion

<5%

Output power

3000 W continuous

Surge rating

6000 W for ten seconds

AC output voltage

120 VAC ± 5%

Input DC voltage rating

12 VDC nominal, 10 to 16 VDC

AC output frequency

60.0 ± 0.05 Hz

Power factor (lag or lead)

0 to 1.0

Peak efficiency

>91%

Efficiency at 3000W

>82%

No load power draw

<3.5 A

DC low voltage shutdown

10 volts

DC over voltage shutdown

16 volts

Charger Specifications

Charging method

Three-stage charge (Bulk, Absorption,
Float)
Two-stage charge (Bulk, Absorption)
The default charging method is three-
stage.

Inverter Specifications

Advertising