TWO-STAGE COOLING WIRING

* Optional dehumidification humidistat switch contacts open on humidity rise.

NOTES:
1. “Y/Y2” Terminal on air handler control board must be connected for full CFM and applications requiring 60 second blower off delay for SEER

enhancement.

2. Remove humidistat jumper on air handler control board.
3. For heat pump applications - set MODE jumper on air handler control board to the HP position.
4. To change quantity of heat during HP defrost cycle - reverse connections at W1 and W2 on air handler control board.

TYPICAL APPLICATIONS

CONTROL WIRING - Air Handler & New UPG HP Systems

Two Stage H/P with York Guard VI Board & Copeland “Ultra Tech”

Conventional Application - Not Hot Heat Pump

THERMOSTAT

AIR HANDLER

BOARD

2 - STAGE SCROLL

HEAT PUMP

R

R

R

G

G

Y2

E

W

W

O

O

O

X / L

X / L

X / L

C

C

Y / Y2

Y1

Y1

Y2 OUT

Y2

W2 OUT

W1 OUT

BS

W2

W1

HUM

COM

HUMIDISTAT *

Y1

UPFLOW

DOWNFLOW

HORIZONTAL RIGHT

HORIZONTAL LEFT