4-2. Projector Control Panel

Indicator Lamps

The projector control panel (Figure 4-1) has several indicator lamps that illuminate to indicate normal
operation and when alarm conditions have been detected. Refer to the chart below for details.

Normal Operation Indicator Lamps

LED

Status of the Unit

Main Power: ON

STANDBY/ON: ON
Lamp: OFF

STANDBY/ON: ON
Lamp: ON

Receiving Remote
Control Signal

POWER

Amber

GREEN

GREEN

REMOTE

OFF

OFF

OFF

Blinking GREEN

CHANGE LAMP

OFF

OFF

OFF

COVER

OFF

OFF

OFF

FAN

OFF

OFF

OFF

TEMP

OFF

OFF

OFF

LAMP

OFF

Blinking GREEN

GREEN

Alarm Indicator Lamps

LED

Status of the Unit

Lamp Failure

Temperature

Failure

Right Panel

Open

Lamp Life Over

(>1000 hours)

Fan Failure

POWER

Amber

Amber

Amber

GREEN

Amber

REMOTE

CHANGE LAMP

RED

COVER

RED

FAN

RED

TEMP

RED

LAMP

RED

Special/Reset Buttons

Press the SPECIAL button (Figure 4-1) to view the
firmware revision level and the current input data
(RGB or Video) for the projector. The TEST
SCREEN (Figure 4-2) will display. If no input is
detected, the message “NO INPUT” will display.

RGB1
TEST SCREEN

FIRMWARE REV
#10011A
SVGA56
H xx.x kHz
V xx.x Hz

VIDEO1
TEST SCREEN

FIRMWARE REV
#10011A
NTSC

Figure 4-2. Test Screens

Press the RESET button (Figure 4-1) to reset all
projector settings to the factory default. Press the
down arrow to change to YES (Figure 4-3) and press
the SELECT button. Press the SELECT button again
to activate the settings and the message “RESET
COMPLETE will display.

RESET

ALL SETTINGS TO
FACTORY DEFAULT

NO
YES

Figure 4-3. Reset Screen