OIL LINE PIPING

First determine whether the pipe system is to be a single
line system or a two line system. All connections must
be absolutely air tight or you will have a malfunction of
the burner. When installing the piping, a good oil filter
should be installed close to the burner. A single line
system is recommended for gravity feed.

A typical single inside tank installations shown in
Figure 6. For installation details for this and other tank
configurations, refer to NFPA31 -- latest edition. All
tank and pipe setups must comply with NFPA31.

BECKETT AFG OIL BURNER

This furnace is equipped with a high static Beckett AFG
oil burner which is designed to produce adequate draft in
nearly any vertically vented application. The burner
employs the latest time tested controls of the highest
quality. The controls consist of a high voltage Beckett
solid state igniter, a Beckett “CleanCut” oil pump with
an integral solenoid valve, and a Beckett R7184B
primary control.

FIGURE 6

TYPICAL SINGLE INSIDE TANK INSTALLATION

6"

2" Cap

Vent Cap

2" Fill Pipe

1-1/4"

Vent Pipe

Return Line

Guage

Bushing,

2" x 1-1/2" or

1-1/4"

Oil Filter

3/8" O.D. Copper

Fuel Tubing

3/8" x 3/8"

Adapter

Gate Valve

3/8" x 4"

nipple

Bushing

Legs (either 1-1/4"x10"

or 1-1/2"x10" nipples)

Oil

Tank

MIS-1823