Cond. unit, Thermostat, Warning – 321 Studios Oil Furnace FLR110D48E User Manual

Page 37: Danger, Fh series wiring diagram, Blower capacitor return area 1 5, 24v. conn, Yc w rh y g rc, Heat hum

Advertising
background image

Manual 2100-422
Page 35

FH SERIES

WIRING DIAGRAM

WHITE

RED

ORANGE

BLUE

BLACK

1

2

3

4

5

BLOWER ASSEMBLY

GROUND

NEUTRAL

HOT

2

1

1

2

3

4

5

6

7

8

9

BURNER ASS'Y

T

T

OIL VALVE

BURNER

MOTOR

IGNITOR

CAD CELL

IGNITOR

L2

L1

CAD CELL

BURNER

MOTOR

VALVE

PURPLE

PURPLE

WHITE

BLACK

BLACK

BLACK

BLACK

BLACK

BLACK

WHITE

GREEN

PURPLE

PURPLE

BLACK

BLACK

BLACK

BLACK

PLUG

#1

PLUG #2

PLUG #3

CONTROL PANEL

HEAT EXCHANGER AREA

UNIT

DOOR

SWITCH

PRIMARY

LIMIT

CONTROL

BACKUP

LIMIT

BROWN

BROWN

BLOWER

CAPACITOR

RETURN AREA

1

5

4047-118 B

24V.

CONN.

COND.

UNIT

Y

C

W

Rh

Y

G

Rc

THERMOSTAT

T87F/Q539A1220

OR EQUIVELANT

LOW

VOLTAGE

HIGH

VOLTAGE

FIELD

WIRING

2

WHITE

WHITE

SEE CHART FOR

HEATING AND COOLING

WIRE COLORS

BLACK

WHITE

GREEN

BLUE

GREEN

WHITE

24V

120V

COM

TRANSFORMER

IF ANY OF THE ORIGINAL WIRE AS

SUPPLIED WITH THIS APPLIANCE

MUST BE REPLACED, IT MUST BE

REPLACED WITH WIRING MATERIAL

HAVING A TEMP. RATING OF AT

LEAST 105°C EXCEPT PRIMARY

LIMIT WIRES. SEE NOTE "1".

WARNING

!

DASHED LINES

REPRESENT FIELD WIRING.

ONLY ONE HEATING

AND COOLING SPEED

CAN BE CONNECTED.

ALL OTHER TAPS

CONNECT TO "SPARE"

TERMINALS.

COOLING SPEED

CONNECTION POINT.

HEATING SPEED

CONNECTION POINT.

IF PRIMARY LIMIT WIRES

ARE TO BE REPLACED,

USE WIRE WITH INSUL.

TEMP. RATING OF 200°C.

5

4

3

2

NOTES

1

*ELECTRICAL SHOCK HAZARD

*DISCONNECT POWER BEFORE

SERVICING.

DANGER

!

COOL

EAC

L2

COM

SPR1

SPR2

SPR3

3

4

240

210

180

150

R

W

G

Y

C

BLOWER CONTROL

T

T

L1

SEC2

SEC1

HEAT

HUM

0.55

LOW (RED)

70°-100°

0.65

LOW (RED)

70°-100°

0.75

MED (BLUE)

60°-90°

0.85

LOW (RED)

70°-100°

1

MED-LOW (ORANGE)

60°-90°

0.85

LOW (RED)

60°-90°

1

MED-LOW (ORANGE)

60°-90°

FACTORY SETTINGS

INPUT

RATE

GPH

UNIT

COOLING BLOWER

SPEED (COLOR)

TEMP.

RISE

RANGE

HEATING BLOWER

SPEED (COLOR)

FH085D36E

FH110D48E

FH110D60E

HIGH (BLACK)

UNIT

MOTOR

CAPACITOR

FH085D36E

1/3

5/370

FH110D48E

1/2

7.5/370

FH110D60E

3/4

15/370

BLOWER CAPACITOR RATING

2

LOW (RED)

730

2 1/2

MED (BLUE)

900

3

HIGH (BLACK)

1160

2 1/2

LOW (RED)

1020

3

MED-LOW (ORANGE)

1280

3 1/2

MED-HIGH (BLUE)

1495

4

HIGH (BLACK)

1640

3

LOW (RED)

1300

3 1/2

MED-LOW (ORANGE)

1460

4

MID-HIGH (BLUE)

1660

5

HIGH (BLACK)

1970

FH085D36E

FH110D48E

FH110D60E

OPTIONAL AIR COND. SETTINGS

NOM.

A/C

TONS

UNIT

CFM @
.50 W C

COOLING BLOWER

SPEED (COLOR)

0.55

LOW (RED)

70°-100°

0.65

LOW (RED)

70°-100°

0.75

MED (BLUE)

60°-90°

0.85

LOW (RED)

70°-100°

1

MED-LOW (ORANGE)

60°-90°

0.85

LOW (RED)

60°-90°

1

MED-LOW (ORANGE)

60°-90°

FACTORY SETTINGS

INPUT

RATE

GPH

UNIT

COOLING BLOWER

SPEED (COLOR)

TEMP.

RISE

RANGE

HEATING BLOWER

SPEED (COLOR)

FH085D36E

FH110D48E

FH110D60E

HIGH (BLACK)

UNIT

MOTOR

CAPACITOR

FH085D36E

1/3

5/370

FH110D48E

1/2

7.5/370

FH110D60E

3/4

15/370

BLOWER CAPACITOR RATING

2

LOW (RED)

730

2 1/2

MED (BLUE)

900

3

HIGH (BLACK)

1160

2 1/2

LOW (RED)

1020

3

MED-LOW (ORANGE)

1280

3 1/2

MED-HIGH (BLUE)

1495

4

HIGH (BLACK)

1640

3

LOW (RED)

1300

3 1/2

MED-LOW (ORANGE)

1460

4

MID-HIGH (BLUE)

1660

5

HIGH (BLACK)

1970

FH085D36E

FH110D48E

FH110D60E

OPTIONAL AIR COND. SETTINGS

NOM.

A/C

TONS

UNIT

CFM @
.50 W C

COOLING BLOWER

SPEED (COLOR)