Alignment and Troubleshooting

4-20

5. LSU Control

Item

Description

LD Power

When “OK” key is pushed after ”ON” message displayed, ”OFF” message
will be displayed after 10 seconds

LSU Motor

If “OK” key is pushed after “ON” displayed, motor will be run. LSU motor

will auto - stop after 10 seconds and ”OFF” message will be displayed.

LSU Ready

If “OK” key is pushed after “ON” displayed, motor will be run. ”1” message

will be displayed.

Hsync

If “OK” key is pushed after “ON” displayed, motor will be run. ”1” message

will be displayed.

6. DEV Control

Item

Description

THV (+)

If “OK” key is pushed after “ON” displayed, THV (+) will be turned on.

THV (-)

If “OK” key is pushed after “ON” displayed, THV (-) will be turned on.

Dev Bias

If “OK” key is pushed after “ON” displayed, Dev Bias will be turned on.

MHV Bias

If “OK” key is pushed after “ON” displayed, MHV Bias will be turned on.

■ ACRONYMS

• DEV – Developing High Voltage
• EDC – Embedded Diagnostic Control
• F/W – Firmware
• HVPS – High Voltage Power Supply
• H/W – Hardware
• LD – Laser Diode
• LSU – Laser Scanning Unit
• MHV – Main High Voltage (Charge Voltage)
• OPC – Optical Photo Conductor
• SCF – Second Cassette Feeder
• THV – Transfer High Voltage