Alignment and Troubleshooting

4-28

2) Vertical White Line

Description : White vertical voids in the image.

3. It may occur due to dirty or

foreign substances are on the window

of the toner cartridge frame.

4. If the fuser is defective,

voids occur periodically at the

top of a black image.

5. It may occur when foreign

substances are on the OPC Drum.

6. Partly depression or

deformation on the surface of the

transfer roller

2. Foreign matter or

toner particles between the toner

cartridge roller and blade. (In case the life of the

toner cartridge has been expired, white

lines or light image occur in

front of the image.)

1. Foreign matter stuck onto the

window of internal lenses

of LSU mirror.

Foreign matter stuck onto the
window : Clean the LSU window
with recommended cleaner(IPA)
Clean the window with a clean
cotton swab.

Replace the toner cartridge.

No 3. : Clean the exposure
window. (toner cartridge)

No. 4. : Open the front cover and
check ribs that corresponds to the
position of the voids. Remove if
found.

If the problems are not solved,
replace the toner cartridge.

Replace the transfer roller if
occured as NO.6

Advertising