Analyzer start – 3Com 3500 User Manual

Page 761

Advertising
background image

analyzer start

761

3500

9000

9400

3900

9300

analyzer start

Starts port monitoring activity on the selected bridge port.

Valid Minimum Abbreviation

an sta

Important Considerations

You must already have an analyzer port configured. First designate a
bridge port to serve as the analyzer port and connect the analyzer to
that port. See “analyzer add” earlier in this chapter for details.

On the CoreBuilder 9000, the analyzer port and the monitor port
must be on the same module.

The MAC address of the analyzer port is displayed when you configure
that port, and when you display the roving analysis configurations on
the system to which the analyzer is attached.

The media type of the analyzer port must match the media type of the
port being monitored. Fast Ethernet and Gigabit Ethernet are the
same media type.

You can use a Fast Ethernet (10 Mbps) port to monitor a Gigabit
Ethernet (100 Mbps) port, but a warning message will be printed. If
the sustained traffic load is greater than 10 Mbps, the analyzer on the
slower port may not see all the frames on the faster port.

When you successfully configure a bridge port to be monitored, all the
data that the monitored port receives and transmits is copied to the
selected analyzer port.

Once a port is selected to serve as a monitor port, the RMON data that
it can record is limited to the RMON groups (statistics, history, alarm,
event, protocolDir, and probeConfig) that do not require hardware
sampling.

If you replace the module that the monitored port resides on with a
module of a different media type, the roving analysis port (RAP)
configuration for the monitored port is reset.