Using the st-305 line transmitter – RIDGID SeekTech ST-305 User Manual

Page 6

Advertising
background image

Ridge Tool Company



Tools For The Professional

TM

SeekTech

®

ST-305

Using the ST-305 Line Transmitter

The ST-305 line transmitter can apply an active tracing signal

to a target conductor in three ways:

Figure 4

Figure 5

Figure 6

Direct Connect – The transmitter’s leads are connected

directly to the target conductor and a suitable ground.

The ST-305 is capable of dual-frequency transmission

(sending two frequencies onto a line simultaneously) in

direct-connect mode. See page 7.
Inductive Clamp – The jaws of the inductive clamp encircle

the target conductor; there is no metal-to-metal contact.

(The inductive clamp is an optional accessory). See page 7.
Inductive Mode (internal coils) – The transmitter is placed

over, and in-line with, a conductor. Its internal antenna

generates a dipole field which energizes the target conductor

below ground, inducing a current into the target conductor.

See page 8.

DANGER! Always connect leads before turning the

transmitter on to avoid electrical shock. Ensure transmitter

is well grounded.

Direct-Connect Method

1. Attach the ST-305 line transmitter to

ground and to the target line

Insert the ground stake into the ground. Connect one of the

cable leads.

Connect the other lead to the target conductor.

Figure 7: Connecting the ST-305 to a Line

Advertising