22

| sBp 1000-1500 e | e sol | e cool

www.stiebel-eltron.com

installation

specification

sBP 1500 e cool

175

175

1032

1220

349

609

956

1179

1319

1629

1849

2154

2255

389

464

759

1054

1349

1600

1710

1900

i01

i07

i07

h22

h43

d46

h22

h22

h28

h02
d47

d35

d01

d35

e02

d02

d36

d36

e01

45°

D

00

00

01

74

23

sBp 1500 e cool

d01 Heat pump flow

Diameter

DN 80

d02 Heat pump return

Diameter

DN 80

d35 Heat source flow optional

Female thread

G 1 1/2

d36 Heat source return optional

Female thread

G 1 1/2

d46 Ventilation

Female thread

G 1/2

d47 Drain

Male thread

G 3/4 A

e01 Heating flow

Diameter

DN 80

e02 Heating return

Diameter

DN 80

h02 Sensor heat pump return

Diameter

mm

9.5

h22 Sensor heat source

Diameter

mm

9.5

h28 Sensor solar cylinder

Diameter

mm

9.5

h43 Thermometer

Diameter

mm

14.5

i01 Flange

Diameter

mm

280

Pitch circle diameter

mm

245

Screws

M 14

i07 Electric emergency/booster heater

Female thread

G 1 1/2

13.2 Fault conditions

In the event of a fault, temperatures of up to 95 °C at 1.0 MPa can

occur depending on the type of heart source used.