Installation, Guarantee, Environment and recycling – STIEBEL ELTRON CFK 5 с 01.01.1998 User Manual

Page 9: Specification, Safety, Appliance descrip- tion, Preparations, Mounting

Advertising
background image

cFK 5 | 9

f

f

push the appliance down so that

it sits fully on the wall mounting

bracket.

f

f

insert the locking tab into the

top aperture of the wall mount-

ing bracket.

f

f

turn the locking tab with a

screwdriver until it clicks into

place.

10.1 Power supply

f

f

connect the appliance to the

power supply with the mains

plug supplied.

11. Specification

11.1 Dimensions and connec-

tions

E

b01 entry electrical cables
i13

Wall mounting bracket

11.2 Wiring diagram

F

r1 electric heating element

n1 temperature controller

F1 safety temperature controller

11.3 Data table

CFK 5

073685

Electrical data
connected load

kW

0.5

power supply

1/n ~ 230 v

Dimensions
height

mm

387

Width

mm

170

depth

mm

110

Weight
Weight

kg

1.2

Versions
Frost protection setting

°c

6

ip rating

ip20

safety category

ii

colour

white

Values
setting range

°c

6-45

installation

7. Safety

only a qualified contractor should

carry out installation, commission-

ing, maintenance and repair of the

appliance.

7.1 General safety instruc-

tions

We guarantee trouble-free operation

and operational reliability only if the

original accessories and spare parts

intended for the appliance are used.

7.2 Regulations, standards

and instructions

DANGER Electrocution

Carry out all electrical con-

nection and installation

work in accordance with relevant

regulations.

!

Damage to the appliance

and environment

observe the type plate. the

specified voltage must match the

mains voltage.

Note

observe all applicable na-

tional and regional regula-

tions and instructions.

8. Appliance descrip-

tion

8.1 Standard delivery

delivered with the appliance:

- 1 wall mounting bracket
- 1 locking tab
- 2 screws
- 2 rawl plugs

9. Preparations

9.1 Installation in bath-

rooms

DANGER Electrocution

Install the appliance ex-

clusively outside safety

zone 2.

C

0

safety zone 0

1

safety zone 1

2

safety zone 2

3

safety zone 3

f

f

ensure that you maintain the

safety clearances of safety

zone 2 towards bath tubs, show-

er cubicles and washbasins.

9.2 Installation site

DANGER Fire

f

ensure that the wall on

which the appliance is

mounted is resistant to tempera-

tures up to at least 90 °c.

f

f

ensure that the installation site is

not below a socket.

f

f

ensure that the installation site is

at least 10 cm away (to the side)

from a socket.

9.3 Minimum clearances

A

f

f

ensure that the minimum per-

missible clearances to adjacent

objects are maintained.

f

f

ensure that the hot air can es-

cape from the appliance without

obstruction.

10. Mounting

D

1 locking tab

2 Wall mounting bracket

3 latching stay

f

f

secure the wall mounting brack-

et to the wall with suitable rawl

plugs and screws.

f

f

offer the back of the appliance

to the wall mounting bracket

and guide the apertures in the

appliance back over the latch-

ing stays in the wall mounting

bracket.

Guarantee

For guarantees please refer to the respective terms and conditions of supply for your country.

!

The installation, electrical connection and first operation of this appliance should be carried out by a qualified

installer.

!

The company does not accept liability for failure of any goods supplied which have not been installed and

operated inaccordance with the manufacturer‘s instructions.

Environment and recycling

Recycling of obselete appliances

Appliances with this label must not be disposed off with the general waste. They must be collected separately and disposed off

according to local regulations.

Advertising