Acclaim Lighting X-Chip Driver IR User Manual

X-chip-driver-ir

Advertising
background image

Descriptions:

24-004-2042-00
Rev 2.2

Congratulations with your purchase of this product.
Read this manual carefully before using our Acclaim Lighting X-CHIP-DRIVER-IR. The

is a

combination of a control interface and tension provider for our X-CHIP LED PCB modules as a LED fixture. A
maximum of 24 channels can be controlled separately.

X-CHIP-DRIVER-IR

Check for transport damage.
You should be in possession of the following items:
1 X-CHIP-DRIVER-IR
1 Manual
1 LED Remote(Infrared Remote Control)
1 IR EYE(sensor)
8 Flat cables for connection
Should you discover transport damage after unpacking the equipment, inform the hauler immediately.
Never connect a damaged device. You may also contact your supplier.

Delivery Packet:

X

X-CHIP-DRIVER-IR

X-CHIP-DRIVER-IR

Main Features:

Technical Specifications:

Operation temperature

Connection

Housing

Ingress Protection Rating

Control Protocol
Listing

Dimensions
Weights

-10 degC to +50 degC

8 output terminal sockets
2 power in and out terminal sockets
2 DMX in and out terminal sockets
1 IR connect socket

PC +UV resistance

IP20
DMX-512 (1990)

CE certified

195(L) x 110(W) x 22(H)mm
200g

Power

Requirement

12-24VDC, 24A Max.

3A(50PCS of X-CHIP-PCB LED Module) capacity for each output(Total 8 ports in 400pcs).
USITT Standard DMX-512(1990) multiplexed digital control.
1~10 patterns plus a sequence of 10 patterns, chase speed & fade time adjustable.
Master/Slave function modes available.
Fully controlled by DMX controller, XB-R1 or Infrared remote.
Loading output modes consists of RGB mode, Color mode, Color &Brightness mode
and Single mode.
DMX Control Mode, Manual Mode and Auto Mode available.
Different Output Group modes for user assignable .
R.G.B color intensity can be adjustable separately.
All work modes and parameters can be set by flipping 10-way Addressing Dip Switch and
8-way Function Dip Switch.

*Please Note: Improvements and specifications in the design of the unit and the manual are subject to change without
any prior written notice.
*Special Note: For reducing signal errors and avoiding signal transmission problems and interference, it is always
advisable to connect 120 ohm impedance DMX signal cable and DMX terminator for signal connection.