The XMIT LEDs flashes simultaneously for approximately 1.5 seconds during the

121.5MHz modulation test.

Following the test the PASS LED will flash at a rate of twice per second for a total period

of 60 seconds to indicate that the SLB 406 is fully functional. Alternatively, the FAIL LED

will flash at a rate of twice per second for a total period of 60 seconds to indicate that

the SLB 406 has malfunctioned. The unit then shuts off.