Summary of minimum requirements, Operating frequencies, Output power – ACR&Artex SLB406 ELT User Manual

Page 35: Activation, Temperature, Fire resistance, Input power, Mechanical characteristics

Advertising
background image

ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

SLB 406 ELT

Page 35 of 43

MAR 27/11

570-6700 Rev. B

Initial Issue DEC 19/2006

Weight

737 g (including battery pack)

Volume

557 cm

3

Design Specifications

RTCA DO-204

RTCA DO-183

COSPAS-SARSAT T.001

Summary of Minimum Requirements

Operating Frequencies

406.028 MHz +/- 2 kHz Bi-phase L; Emission designator G1D

121.5 MHz +/-6.0 kHz AM; Emission designator A3X

Output Power

406 MHz: 37 dBm ± 2 dBm (3.16W Min to 7.94 W Max) (440 ms / 50 sec) PERP or

EIRP for 24 hours @ -20ºC to +55ºC

121.5 MHz: >/= 20.0 dBm (100mW) PERP for 50 hours or EIRP for 48 hours @ -20ºC

to +55ºC

Activation

Manual or Auto Activation Lanyard

Temperature

Storage: -55ºC to +85ºC

Operational: -20ºC to +55ºC

Fire Resistance

15 sec. flame per RTCA/DO-204 §2.3.7.1

Input Power

None

Mechanical Characteristics

Vibration: 10 G’s, 5Hz to 2000Hz

Shock: 50 G’s for 11 ms