Exchange_t1_frame – ACS AET63 BioTRUSTKey User Manual

Page 21

Advertising
background image

P1

APDU parameter byte 1

P2

APDU parameter byte 2

Lc

APDU command data length

BYTE x

APDU command data

Le

Expected APDU response data length (Le = 0 means no data is expected from the
card)

NOTE

With the T=0 communication protocol it is not possible to transmit data to the card
and from the card in a single command-response pair. Hence, only either Lc or Le
can be greater than 0 in an EXCHANGE_APDU command when a T=0 card is in the
reader. If both parameters have a value greater than 0, the AET63 does not execute
the command and returns an error status.

Response data format

BYT

E 1

...

...

BYT

E N

SW1

SW2

BYTE x

Response data from card (if any)

SW1, SW2

Status code returned by the card.

7.4.4.

EXCHANGE_T1_FRAME

To exchange an APDU (Application Protocol Data Unit) command/response pair between the MCU
card inserted in the AET63 and the host computer using T1 protocol.

Command format

Instruction

Code

Data length

Data

LEN

T1 BLOCK FRAME

A1

H

LEN

Length of APDU command data, N

DATA

T1 Block frame to be sent to the card

Response data format

BYTE 1

...

...

BYTE

N

BYTE x

Response T1 Block from card (if any)

Document Title Here