6.1.2.

Extended Command

A command consists of six protocol bytes and a variable number of data bytes and has the following
structure:

Byte

1

2

3

4

5

6 ... N+5

(N>0)

N+6

Header

Instruction

Data Length = N

Data

Checksum

FF

H

Data

Length

N

Header

01

H

to indicate the start of a standard command.

02

H

to indicate the start of an encrypted command (support from firmware 0.67

onwards, only used in PTVerifySC

(*)

and PTVerifySCAll

(*)

)

Instruction

The instruction code of the command to be carried out by the AET63.

Data Length

Number of subsequent data bytes, and is encoded in 3 bytes. The first byte is FF

H

.

The second byte and the third byte represent data length N.

Data

Data contents of the command.

For a READ command, for example, the data bytes would specify the start address
and the number of bytes to be read. For a WRITE command, the data bytes would
specify the start address and the data to be written to the card.

The data bytes can represent values to be written to a card and/or command
parameters such as an address, a counter, etc.

Checksum

The checksum is computed by XORing all command bytes including header,
instruction, data length and all data bytes.

Note (*) :

Please refer to “BioTRUSTKey API Manual.doc” for the descriptions of PTVerifySC
and PTVerifySCAll.

6.2. Response

The response from the AET63 to any command depends on whether the command has been
received by the reader without error (e.g., checksum error).

6.2.1.

No Transmission Error with Normal Response (Length < 255 bytes)

The response by the AET63 to a correctly received command consists of three protocol bytes, two
status bytes and a variable number of data bytes and has the following structure:

Byte

1

2

3

4

5 ... N+4

(0<N<255)

N+5

Header

SW1

SW2

Data length = N

Data

Checksum

Header

01

H

to indicate the start of the normal response.

02

H

to indicate the start of an encrypted response (support from firmware 0.67

onwards, only used in PTVerifySC

(*)

and PTVerifySCAll

(*)

)

SW1

Indicates the command execution status:

90

H

= command

successfully

executed

60

H

=

error in command data; command cannot be executed