Maintenance, Cleaning – Activeforever Lotus Water Treatment System (Replacement Filter) User Manual

Page 11

Advertising
background image

FIGURE 6

MAINTENANCE

During the conditioning process, any loose carbon dust is removed
from the carbon-block filter. This is a normal characteristic of carbon-
block filters and you will only see this happen during this process. Do
not drink this water. Discard it or use it to water your house plants.

Repeat the conditioning process 3 more times using more fresh water with each cycle.
After 4 cycles, wash out your clean water carafe. With a mild detergent.

Once this is done, your water processor is ready to provide you once again with
microbiological safe, clean drinking water.*

The carbon-block filter doesn’t require submersion in water to activate it. DO NOT
SOAK THE CARBON-BLOCK FILTER
in water prior to use. (FIGURE 5)

When using a new carbon-block filter, initially you may experience
some sputtering during first dispense. This is perfectly normal and
usually stops when the filter has become thoroughly soaked
(after several additional cycles).

Never attempt to reuse a previously used carbon-block filter.

Always ensure that the carbon-block filter is in place prior to use. The
treatment process will not begin without the carbon-block filter in place.

CLEANING:

Through normal use, as with any household appliance, occasional cleaning is necessary.

For dust, smears, grease and other everyday stains that may accumulate on your unit, simply wipe with a damp cloth.

The clean water carafe, lid, pre-filter screen and the carbon-block filter housing cap can be hand washed with a mild
detergent. DO NOT PUT THEM IN THE DISHWASHER.

We recommend cleaning the Processing Carafe approximately once a year by following the instructions below:

1.

Use 1/2 Quart ( Approx. 1/2 Liter) of undiluted white vinegar and pour it directly into the Processing Carafe.
Without the pre-filter screen in place. DO NOT ADD ANY WATER!

2.

While holding the Processing Carafe over the kitchen sink, swish the vinegar around in the Processing Carafe
for 30 seconds.

3.

To drain; invert chamber.

4.

Rinse the Processing Carafe thoroughly with fresh water. To remove any remaining water, upright chamber and
gently lift on the spring drain valve with your finger.

5.

Install Processing Carafe.

Do not process vinegar through your unit.

DO NOT put the Processing Carafe in your dishwasher, (FIGURE 6).
The heat and detergent will cause damage.

Local water conditions may require more frequent cleaning.

9

FIGURE 5

*Tested and verified by independent laboratory testing for the bacterial and protozoa
claims on the Performance Data List on page 16. NSF Certification for a microbiological
claim is for Cyst Reduction only.

Advertising