Display configuration, Coupling, Ii – 1 installation set u p – ACU-RITE VUE User Manual

Page 44

Advertising
background image

30

II – 1 Installation Set

u

p

U

In the Error Monitor field, select whether the system will monitor,
and display encoder errors by selecting ON, or OFF. When an error
message occurs, press the C key to remove it.

Display Configuration

The Display Configuration form is where the operator determines
which axes are displayed, and in what order.

U

Scroll to the desired display and press ENTER.

U

Press the ON/OFF soft keys to turn the display on, or off. Press the
RIGHT/LEFT arrow keys to select the axis label.

U

Scroll to the Input field.

U

Scroll to the Display Resolution field. Press the COARSER, or FINER
soft keys to select the display resolution.

U

Scroll to the Angle Display field if the encoder type is set to Rotary.
Press the ANGLE soft key to display the position as 0° - 360°, ±
180°, ± infinity, or RPM.

Coupling

U

Press the numeric keys associated with the encoder input on the
back of the unit. Press the + or - soft keys to couple a second input
with the first. The input numbers are displayed next to the axis label
indicating that the position is a coupled position (i.e. “2 + 3”).

The encoder resolution and count direction can also be
established by just moving each axis.