11

Mechanical Specifications

Electrical Specifications

90°

360°

1 Count
(Phased)

Channel R+

1

0

Channel
A+

1

0
1
0

Channel
B+

1

0
1
0

Channel B-

Channel A-

Channel R-

1

0

Parameter

Digital

Output Signals

Incremental signals

Signal levels

Reference Mark signals

Signal level

Power Supply

Square-wave voltage signals.

Channels A and B, in 90°

quadrature relationship

Differential - TTL

Square-wave pulse

Differential - TTL

5.1 ± 0.1 VDC @ 140 mA max.

I

OH

=(High level output current) = 20mA

V

OH

=(High level output voltage) >2.5Vdc

I

OL

=(Low level output current) = -20mA

V

OL

=(Low level output voltage) < 0.5Vdc

Connecting cable:

Length = .61m [2 ft]

Armor

Connector: DE-9P

Mechanical Specifications

Digital

Resolution

5µm [0.0002 in.]

Grating pitch

100µm [0.00393 in]

Scale medium

Reflective Metal Tape

Accuracy @ 20° C

± 15µm/M [0.00018 in/ft]

Max. cable length

22.9m [75 ft.] VRO / 10.7m [35 ft.] DRO

Measuring length

6240mm [246”] - 19,640mm [773”]

Force required to move
reading head

± 3.3 Newtons [0.75 lbs]

Max. slew speed

1 M/sec [40 in/sec.]

Operating Environment:
Temperature

0° to 40° C [32° to 104°F]

Relative Humidity

20% to 95% (non-condensing)

Storage Environment:
Temperature

-40° to 60° C [-40° to 140°F]

Humidity

20% to 95% (non-condensing)

Weight w/cable

1 kg + 3.2kg/m [2.2 lbs. + 0.18 lbs/in] of measuring length

Reference Mark Interval

100mm [3.937”] Distance encrypted