5

• Attach this section to the machine using two [1/4-20 x

1-1/4”] M6 x 30mm SHCS and washers provided in the
hardware kit.

• Align the top of the section parallel to the axis travel to

within [.012”] .3mm and secure the fasteners.

• Center sections can be mounted in random order.
• Place the 2mm spacer provided in the hardware kit into

the scale clip as shown.

• With the roll pins already installed, insert the left end of

the center section into the scale clip and butt it to the
mounted end section. Tap the end of the center section
with a soft hammer to seat it against the 2mm spacer.

• Align the top of the section parallel to the axis travel to

within [.012”] .3mm. Transfer punch the furthest right
end mounting hole to the mounting surface.

• Remove the center section, drill and tap the location for

an [1/4-20 x 1/2 “] M6 x12mm deep.

• Re-insert the center section back into the scale clip as

done previously, seating it against the 2mm spacer.

• Attach the right end to the machine but do not tighten.
• Transfer punch remaining mounting holes by aligning the

top surface to within [.012”] .3mm to the axis travel over
each mounting hole. Remove the center section, drill and
tap the locations for an [1/4-20 x 1/2 “] M6 x12mm deep.

RTV

• Reinsert the center section back into the scale clip as done

previously, seating it against the 2mm spacer.

• Attach the right end to the machine but do not tighten.

Clean off any excessive RTV sealant.

Center section installation

2mm Spacer

2mm Spacer

Center scale

section

Roll pins installed

Scale clip

Transfer punch

furthest mounting

hole

[1/4-20 x 1/2 “]

M6 x12mm SHCS

and washer

[1/4-20 x 1-1/4”]

M6 x 30mm

SHCS and washer

• Apply RTV to the two sealant grooves in the right end on

all three sides as done previously. Seal the seated ends of
the spring pins, keeping the end and inside of the section
free of sealant.

• Slide the scale clip over the end of the scale section up to

the stop in the scale case.

• Clean off any excess RTV on the outside of the case.
• Now apply RTV Silicone Rubber to the sealant grooves in

the left end keeping the end and inside of the section free
of sealant.

Center section(s)

This end first

• Align the top surface to within [.012”] .3mm to the axis

travel measuring over each mounting hole. Secure the
scale case in place maintaining the alignment.

• Turn the handle of the 2mm spacer forward and remove it

through the bottom of the scale clip.

Remaining section(s) installation

• Mount any remaining center sections and the right end

section to the machine repeating this procedure. Use the
2mm spacer each time to set the required gap between
each section. Complete the next step prior to drilling and
tapping the right end mounting holes.

End

section

Center section

To be within [.012”] .3mm to the

axis travel

[1/4-20 x 1/2 “]

M6 x12mm SHCS

and washer

Advertising