Enc 250 – ACU-RITE ENC 250MS User Manual

Page 5

Advertising
background image

Acu-Rite Companies Inc.

ENC 250

MULTI-SECTION

4

Machine

casting

A variety of mounting conditions can be accommodated.

• The machine configuration determines the brackets

required to install the encoder.

• Two typical mounting conditions are shown; reading head

mounting plate, and a three piece combination assembly for
mounting the reading head to the machine.

• The [8-32] 4mm SHCS for mounting the reading head is a

standard low head style fastener, supplied with the
mounting hardware.

• Tool requirements are listed on page 2.

• Due to the long length of the encoder sections, the

installation illustrations have been modified.

In most cases, the sections have been shorten to
accommodate the information that they are presenting.

Please keep this in mind as the encoder is being installed.

• This combination typically applies to a lathe where the

cross feed over hangs the bed mounting surface.

• A wide range of combination lengths are available.

Three piece combination bracket ...

• The mounting plate typically applies to surfaces that are

flush, or slightly offset.

Reading head mounting plate ...

Machine

axis

Machine

casting

Mounting plate

ENC 250 encoder

Encoder reading

head

Machine

axis

Combination

bracket

assembly

ENC 250 encoder

Encoder reading

head

• Tap two roll pins into the extruded slots in the “left end

section” as shown. Pins should protrude approximately [5/8”]
15.87mm.

• The seams on the roll pins face towards the inside of the

scale case.

• Repeat this step for all middle scale sections, inserting the

roll pins into the right end of each.

Insert roll pin with open slot

facing in as shown

Roll Pin

Enlarged end

view

Left end section

• Apply RTV Silicone Rubber to the two sealant grooves in

the left end section. The sealant must be applied on all
three sides of the case. Seal the seated ends of the spring
pins. Keep the end and inside of the section free of
sealant.

• Slide the scale clip over the end of the scale section to the

stop machined in the scale case. There is sufficient spring
in the clip to clamp it securely around the case.

• Clean off any excess RTV on the outside of the case.

Seated end of pin

Scale clip

• Hold the left end section against the selected mounting

surface and transfer punch one mounting hole.

• Remove section, drill and tap the location for a

[1/4-20 x 1/2”] M6 x12mm deep minimum.

• Attach the section to the machine, and align the top

surface to within [.012”] .3mm of the axis travel.
Measuring directly over each mounting hole location.

• Transfer punch the second mounting hole. Remove the

section; drill and tap second hole location for a
[1/4-20 x 1/2”] M6 x12mm deep.

Transfer punch (1)

mounting hole location to

the machine surface

Left end

section

Mounting Requirements

Scale Case Installation Procedure

Sealant groves (2)

Left end section installation

RTV

Advertising