Readout Specifications

DRO 200T

22

Readout Specifications

Characteristic

Specification

Operating conditions

0° to 40°C (32° to 104°F)

25% to 85% relative humidity (non-condensing)

Storage conditions

-40° to 60

°

C (-40° to 140

°

F)

25% to 95% relative humidity (non-condensing)

Input requirements

Voltage:

Frequency:

Current:

115VAC or 230VAC (+/-20%), single phase

47-63 Hz

300ma @115V, 150ma @230V

Fuse

115V operation: ½ A, 250V, 3AG, Slo-blo

230V operation: ¼ A, 250V, 3AG, Slo-blo

Encoder input

Position signals: channels A & B

TTL square wave signal in quadrature
(90

°

nominal phase relationship)

Maximum input rate: 50 kHz

Reference signal: TTL square wave

Size

12.5”W x 5.125”D x 6.5H”

Weight

7.5 lbs.

Mounting

Bottom: two ¼ -20 threaded inserts

FCC compliance

Class A