Data logging – ACU-RITE DRO 200T User Manual

Page 34

Advertising
background image

DRO 200T

Troubleshooting

27

If the problem remains in the same display, the readout is in error.

If the problem follows the connection change, the linear encoder may be in
error. Refer to the Checking the Linear Encoders section of your encoder

reference manual.

Display overflow errors are indicated by dashes in all digits in an axis display.
A numeric overflow occurs when the intended measurement is too large for the
eight-digit display. Clear the error by returning the machine table into an area
where measurements can again be displayed, selecting a lower display resolution,

setting a new preset, or zeroing the display.

This error may also occur when using the automatic compensation routine while
setting the LEC parameter. An error indicates that the calculated compensation
factor was outside the acceptable range of -9999 to +9999, and usually is the
result of incorrectly entering data. Clear the error and return to the beginning of

the linear error compensation routine. Refer to page 18.

Data Logging

The readout collects information about itself while it is being used. This

information is stored in memory for review at a later time.

Press and hold the

.

key until the software version is displayed. Then press the

SETUP

and

MM

keys simultaneously. Use the

X

key to cycle through the following

information.

Power on time—displayed in decimal hours.

Scale travel distance—the travel distance for each axis is scrolled one after the

other.

Last 3 errors—the most recent three errors are remembered and messages for

the errors are scrolled one after the other.

Advertising
This manual is related to the following products: