Other errors – ACU-RITE DRO 200T User Manual

Page 33

Advertising
background image

Troubleshooting

DRO 200T

26

Keypad test. Begin by pressing the

X

key, and then press each key (except

the

X

key) in turn to verify that it is functioning properly. When a key is

pressed, the X-axis activates a “plus sign” indicator and increments a count. When

you release the key, the plus sign disappears.

Display test. Begin by pressing the

X

key. All indicators in all displays will

light. Visually check each portion of each display to ensure that they are

functioning properly.

Press

X

again to test the display electronics. All decimal points on all displays

will light momentarily, and then each segment of all displays will light in turn.
Press

X

again, and each digit of all displays will light, one digit at a time,

starting with the leftmost digit and moving to the right.

Exit the diagnostics by pressing the

X

key.

Other Errors

The readout includes built-in test and error-checking circuitry. This circuitry
identifies errors that occur, and reports the problem to the operator. Errors are

reported by scrolling messages in the X-axis display.

Loss of power is indicated by the “Power was off” message. Loss of power means
that power to the readout has been interrupted. Since power to the encoders has
also been interrupted, position information may no longer be accurate. Press the

CLEAR

key to clear the error message. All display measurements will be zeroed.

Refer to page 4 for information about position recovery.

Counting errors are indicated by the “Scale miscount” message, telling you in
which axis the miscount occurred. Counting errors result from distorted electrical
signals from an encoder. These signals can be a result of an encoder malfunction,
misalignment, mounting problems, or electrical interference. Press the

CLEAR

key to

clear

the error message. The axis display (for both absolute and incremental

measurements) will be zeroed. Follow these steps to determine if your difficulties

are associated with the readout or with the encoder.

Ensure that the linear encoder connectors are correctly seated.

Swap linear encoder cables at the readout to see if the problem still appears in

the same display.

Advertising
This manual is related to the following products: