WARNING

NEVER ASCEND ABOVE THE CEILING! You must not ascend above
the ceiling during your decompression. In order to avoid doing so by
accident, you should stay somewhat below the ceiling.

Display below the floor
The blinking ASC TIME and an upward pointing arrow indicate that you are below the
floor. You should start your ascent immediately. The ceiling depth is shown on the left
side, and the minimum total ascent time on the right side, of the center window. Below is
an example of a decompression dive without Deep Stops, below the floor.

UPWARD POINTING ARROW, BLINKING ASC

TIME AND AN ALARM TELL YOU TO ASCEND. MINIMUM

TOTAL ASCENT TIME INCLUDING MANDATORY SAFETY

STOP IS 15 MINUTES. CEILING IS AT 3 M.

Display above the floor
When you ascend above the floor, the ASC TIME display stops blinking and the upward
pointing arrow disappears. Below is an example of a decompression dive above the floor.

UPWARD POINTING ARROW HAS

DISAPPEARED AND ASC TIME LABEL HAS

STOPPED BLINKING, MEANING YOU ARE IN

THE DECOMPRESSION RANGE.

Decompression will now begin, but is very slow. You should therefore continue your ascent.

Display at the ceiling zone
When you reach the ceiling zone, the display will show you two arrows pointing at each
other (the “hour glass” icon). Below is an example of a decompression dive at the ceiling
zone.

TWO ARROWS POINT AT EACH OTHER

“HOUR GLASS”. YOU ARE IN THE OPTIMUM CEILING

ZONE AT 3 M. AND YOUR MINIMUM ASCENT TIME IS

15 MINUTES.

During the decompression stop, ASC TIME will count down towards zero. When the ceiling
moves upwards, you can ascend to the new ceiling. You may surface only after the ASC
TIME and CEILING labels have disappeared, which means that the decompression stop
and any Mandatory Safety Stop have been completed. You are advised, however, to stay
until the STOP sign has also disappeared. This indicates that the three minute
Recommended Safety Stop has also been completed.

Display above the ceiling
If you ascend above the ceiling during a decompression stop, a downward pointing arrow
will appear and a continuous beeping starts.

29