Diving in nitrox mode (divenitrox), Before diving in nitrox mode, Default nitrox settings – SUUNTO Vyper2 User Manual

Page 30: Oxygen displays, 30 6.2.2. oxygen displays

Advertising
background image

DECOMPRESSION DIVE, ABOVE CEILING.

NOTE DOWNWARD POINTING ARROW, ER WARNING

AND ALARM. YOU SHOULD IMMEDIATLY (WITHIN

3 MINUTES) DES C END TO OR BELOW CEILING.

In addition, an Error warning (Er) reminds you that you have only three minutes to correct
the situation. You must immediately descend to, or below, the ceiling.
If you continue to violate the decompression, the dive computer will go into a permanent
Error Mode. In this mode, the instrument can only be used as a depth gauge and timer.
You must not dive again for at least 48 hours. (See Section 5.6. Error conditions).

6.2. Diving in NITROX mode (DIVEnitrox)
NITROX mode (DIVEnitrox) is the second dive mode available in Suunto Vyper2 and is
used when using oxygen- enriched gas mixtures.

6.2.1. Before diving in NITROX mode
If set to the NITROX mode, the correct oxygen percentage of the gas in your cylinder must
always be entered into the computer to ensure correct nitrogen and oxygen calculations.
The dive computer adjusts its mathematical nitrogen and oxygen calculation models
accordingly. The dive computer will not accept fractional percentage values of oxygen
concentration. Do not round up fractional percentages. For example, 31.8% oxygen should
be entered as 31%. Rounding up will cause nitrogen percentages to be understated and
will affect decompression calculations. If you want to adjust the computer to provide more
conservative calculations, use the personal adjustment feature to affect decompression
calculations, or reduce the PO

2

setting to affect oxygen exposure according to the entered

O

2

% and PO

2

values. Calculations based on nitrox use result in longer no-decompression

times and shallower maximum depths than diving with air.
As a safety precaution, the oxygen calculations in the computer are made with an oxygen
percentage of 1% + set O

2

% .

When the dive computer is set in NITROX mode, the Dive Planning mode calculates using
the O

2

% and PO

2

values that are currently in the computer.

To set the nitrox mixes, refer to Section 5.7.3. Setting the nitrox values.

Default nitrox settings
In NITROX mode, the Suunto Vyper2 allows you to set 1 or 2 nitrox mixes containing 21-
99% oxygen.
In the NITROX mode, the default setting for MIX1 is standard air (21% O

2

). It remains in

this setting until the O

2

% is adjusted to any other percentage of oxygen (22% - 99%). The

default setting for maximum oxygen partial pressure is 1.4 bar, however you are able to
set it in the range of 0.5 - 1.6 bar.
MIX2 is set to OFF by default. To set MIX2 , refer to Section 6.2.4. Gas change and multiple
breathing gas mixes
. Oxygen percentages and maximum oxygen partial pressures for
MIX2 are stored permanently.

6.2.2. Oxygen displays
When NITROX mode is activated, the display will show the information in the figure below.
In NITROX mode, the maximum operational depth is calculated based on set O

2

% and

PO

2

values.

30

Advertising