Altitude diving, Oxygen exposure – SUUNTO Vyper2 User Manual

Page 46

Advertising
background image

No-decompression time limits (mins) for various depths (ft) for the first

dive of a series

Personal Mode / Altitude Mode

Depth

(ft)

P2/A2

P2/A1

P2/A0

P1/A2

P1/A1

P1/A0

P0/A2

P0/A1

P0/A0

5
4
4
3

6
5
4
4

8
6
5
4

6
5
4
4

8
6
5
4

9
7
6
5

8
6
5
4

9
7
6
5

10
9
7
6

120
130
140
150

9.2.3. Altitude diving
The atmospheric pressure is lower at high altitudes than at sea level. After traveling to a
higher altitude, you will have additional nitrogen in your body, compared to the equilibrium
situation at the original altitude. This "additional" nitrogen is released gradually over time
and equilibrium is restored. It is recommended that you acclimatize to a new altitude by
waiting at least three hours before making a dive.
Before high-altitude diving, the instrument must be set to the Altitude Adjustment mode
to adjust the calculations for the new altitude. The maximum partial pressures of nitrogen
allowed by the mathematical model of the dive computer are reduced according to the
lower ambient pressure.
As a result, the allowed no-decompression-stop limits are considerably reduced.

9.3. Oxygen exposure
The oxygen exposure calculations are based on currently accepted exposure time limit
tables and principles. In addition to this, the dive computer uses several methods to
conservatively estimate the oxygen exposure. For example:

the displayed oxygen exposure calculations are raised to the next higher percentage
value

for recreational scuba diving, the recommended upper limit of 1.4 bar PO

2

is used as

a default

the CNS % limits up to 1.6 bar are based on 1991 NOAA Diving Manual limits

the OTU monitoring is based on the long-term daily tolerance level and the recovery
rate is reduced

Oxygen related information displayed by the dive computer is also designed to ensure
that all warnings and displays occur at the appropriate phases of a dive. For example, the
following information will be shown before and during a dive when the computer is set in
NITROX mode:

the selected O

2

% on the alternative display

OLF% alternative display for either CNS% or OTU% (whichever is larger)

audible alarms are given and the OLF value starts to blink when the 80% and 100%
limits are exceeded

audible alarms are given and the actual PO

2

value blinks when it exceeds the preset

limit

in dive planning, the maximum depth according to the O

2

% and maximum PO

2

selected

46

Advertising