DESCRIPTION

The hood may be in the filtering or the ducting version.

Filtering version (Fig. 1): The hood aspirates the kitchen air saturated with fumes and odours, purifies it through

the grease filters and charcoal filter and returns clean air into the room. For constant efficiency, the charcoal filter must
be replaced periodically. The charcoal filter is not supplied.

Ducting version (Fig. 2): The hood aspirates the kitchen air saturated with fumes and odours, passes it through the

grease filters and expels it to the outside through an outlet pipe. With this version the charcoal filter is not required. Decide
from the outset on the type of installation (filtering or ducting). For greater efficiency, we recommend you install the hood
in the ducting version (if possible).

INSTALLATION

ATTENTION: Two persons are required for proper installation; the unit should be installed by a qualified
operator.

INSTALLATION IN DUCTING VERSION: Before fixing, the outlet pipe for air evacuation to the outside must be installed.

Use an outlet pipe with: – minimum indispensable length; – minimum possible bends (maximum angle of bend: 90°); – certified
material (according to the State); – an as smooth as possible inside. It is also advisable to avoid any drastic changes
in pipe cross-section (recommended diameter: 150 mm). For air evacuation to the outside, follow all the other instructions
given on the “Warnings” sheet. Prepare the power supply within the telescopic chimney (for the electrical connection, follow
all the other instructions on the “Warnings” sheet).

1.

Mount the plate of the electrical system (depending on the model) fixing it with 2 screws and 2 metal washers

(Fig. 3).

2.

Fixing to the wall: Draw a line on the wall in vertical line with your hob. Mark the first 2 holes to be drilled in the

wall, respecting the distances indicated in Fig. 4. Drill the 2 holes and fit the screw anchors provided. Fix the metal bracket
(A) to the wall using the 2 holes just drilled (Fig. 5); the screws for fixing the bracket are provided. Use the 2 cut-out triangles
on the bracket to position it exactly along the vertical axis of the hood.
Hang the hood on the bracket (Fig. 6). Adjust the horizontal position moving the hood to the right or left so that it is aligned
with the wall units. If you also need to adjust the hood in height, operate on the adjusting screws (B) provided. When
adjustment has been completed, without removing the hood, mark the other 4 holes to be drilled (C) in the wall. Remove
the hood and drill the holes marked (8 mm diameter). Then use the 4 screw anchors and the 4 screws provided for final
fixing.

3.

Install the flange in the device air outlet and press slightly (Fig.7).

4.

Fixing the telescopic flues:

- Assemble the tube support using a 4 screws kit (Fig. 8); then, by means of the screw anchors and screws (F) provided,
fix the bracket to the ceiling in such a way that it is positioned along the axis with your hood (Fig.9).
- Connect the air outlet pipe to the air vent of the hood.
- Use a flexible pipe and lock it to the air vent of the hood with a metal hose clamp - Fig.10 (pipe and clamp are not provided).
- For exhaust hoods, turn the upper flue over so that the air exhaust grid is in the lower section (Fig.11).
- Plug in the hood.
- Insert the telescopic flues by placing them on the hood and making sure that the wing-nuts of the lower flue fit correctly
(Fig. 12); extend the upper flue to the ceiling and secure with the 2 screws (H) - Fig.12.

INSTALLATION IN FILTERING VERSION: Prepare the power supply within the telescopic flues (for the electrical

connection, follow all the other instructions on the “Warnings” sheet).

Fixing to the wall: for fixing to the wall refer to the instructions for the ducting version (see points 1, 2, 3), then continue

with the instructions below.

Fixing the telescopic flues:

- Assemble the tube support using a 4 screws kit (Fig.8).
- Then, by means of the screw anchors and screws (F) provided, fix the bracket to the ceiling in such a way that it is positioned
along the axis with your hood (Fig.9).
- Mount the flange on the hood in correspondence to the air outlet point (Fig.13).
– Take the air baffle and fit a flexible pipe to it (125 mm diameter) locking it with a metal hose clamp (pipe and clamps
are not provided). Fit the air baffle to the upper flue (Fig.14) with 4 screws.
- Connect the flexible pipe to the flange on the air vent (Fig.15).
- Plug in the hood.
- Insert the telescopic flues by placing them on the hood and making sure that the wing-nuts of the lower flue fit correctly
(Fig. 12); extend the upper flue to the ceiling and secure with the 2 screws H (Fig.12).
- Bear in mind that the Filtering Version requires a charcoal filter; verify whether this filter is already fitted and, if not,
install the filter: open the crystal element by turning it towards the outside (Fig. 16); remove the grease filter by pressing
the retainer and turning the filter towards the outside (Fig. 17); insert the charcoal filter by resting its lower edge and
turning it towards the hood (Fig. 18).